4 Valve Description
58 of 100
4.6.1.3 Design details
Design
▪
Lift check valve to API 602
▪
Tested to API 598
▪
Body made of forged steel
▪
Bolted cover
▪
Reduced bore
▪
Solid check disc
▪
Integral seat - ST6 (HF)
▪
Fully confined cover gasket
▪
Spring ensures reliable shut-off
▪
The valves satisfy the safety requirements of Annex I of the European Pressure
Equipment Directive 97/23/EC (PED) for fluids in Groups 1 and 2.
▪
The valves do not have a potential internal source of ignition and can be used in
potentially explosive atmospheres, Group II, category 2 (zones 1+21) and
category 3 (zones 2+22) to ATEX 2014/34/EU.
Variants
▪
Seal-welded body/cover joint
▪
Full bore
▪
Butt weld ends
▪
Version in compliance with TA-Luft (German Clean Air Act) to VDI 2440 for
temperatures up to 400 °C
▪
NACE standard
▪
Other flanged end designs or butt weld ends to ASME B16.25
▪
Other trims