![KSB ECOLINE FYC Operating Manual Download Page 60](http://html1.mh-extra.com/html/ksb/ecoline-fyc/ecoline-fyc_operating-manual_2006442060.webp)
4 Valve Description
60 of 100
4.6.1.5 Materials
901
160
411
950
351
515
100
Table 65: Parts list
Part No.
Description
Material
A 105
Trim 8
A 182 F11
Trim 5
A 182 F22
Trim 5
A 182 F304
Trim 2
A 182 F316
Trim 10
100
Body
A 105
A 182 F11
A 182 F22
A 182 F304
A 182 F316
160
Cover
A 105
A 182 F11
A 182 F22
A 182 F304
A 182 F316
351
Check disc
A 182 F6a
A 182 F6a + STL6
A 182 F6a + STL6
A 182 F304
A 182 F316
411
Joint ring
304 + graphite
304 + graphite
304 + graphite
304 + graphite
316 + graphite
515
Seat ring
STL6 (integral)
STL6 (integral)
STL6 (integral)
304 (integral)
316 (integral)
901
Bolt
A 193 B7
A 193 B16
A 193 B16
A 193 B8
A 193 B8M
950
Spring
SS304
SS304
SS304
SS304
SS316
4.6.1.6 Function
The main components of the lift check valves are the body (100), the cover (160) and
the check disc (351).
Seat/disc interface
The integral seating surfaces in the body (100) are hard-faced. The check disc (351) is
spring-loaded.
Bonnet/cover seal
The cover (160) is bolted to the body (100). The joint is sealed by a joint ring (411).
4.6.2 ECOLINE PTF 800-2500
4.6.2.1 Operating data
Table 66: Operating properties
Characteristic
Value
Nominal pressure
Class
800 - 2500
Nominal size
NPS
½
" - 2"
Max. permissible pressure
431
bar /
6250
PSI
Min. permissible temperature
0 °C / 32 °F
Max. permissible temperature
+538
°C /
+1500
°F
Temperatures < 0 °C on request
Selection as per pressure/temperature ratings
(
ð
Section 4.6.2.4, Page 62)