4 Valve Description
54 of 100
Seat/disc interface
The seat ring is an integral part of the body (100). The flexible wedge (361) is
fastened to the stem (200) by a "T" joint and guided by lateral guide bars in the body
(100).
Bonnet/cover seal
The body (100) and the yoke (166) are connected by studs (902) and nuts (920.2). The
joint is sealed by means of a joint ring (411).
4.5.5 ECOLINE GTB 800
4.5.5.1 Operating data
Table 57: Operating properties
Characteristic
Value
Nominal pressure
Class 150 - 800
Nominal size
NPS ½'' - 2''
Max. permissible pressure
136 bar
Min. permissible temperature
0 °C
Max. permissible temperature
427 °C
Temperatures < 0 °C on request
Selection as per pressure/temperature ratings
(
ð
Section 4.5.5.4, Page 55)
4.5.5.2 Fluids handled
▪
Steam
▪
Explosive fluids
▪
Combustible fluids
▪
Liquids containing gas or vapour
▪
Gas
▪
Fluids posing a health hazard
▪
Toxic fluids
▪
High-temperature hot water
▪
Highly aggressive fluids
▪
Condensate
▪
Corrosive fluids
▪
Valuable fluids
▪
Volatile fluids
▪
Fluids containing mineral oils
▪
Oil
▪
Feed water
▪
Thermal oil
▪
Other fluids on request.
Summary of Contents for ECOLINE FYC
Page 4: ...Contents 4 of 100 9 5 EU Declaration of Conformity for ECOLINE GLB 150 600 95 Index 96...
Page 98: ......
Page 99: ......