4 Valve Description
64 of 100
4.7 Swing Check Valves to ANSI/ASME
4.7.1 ECOLINE SCC 150-600
4.7.1.1 Operating data
Table 71: Operating properties
Characteristic
Value
Nominal pressure
Class 150 - 600
Nominal size
NPS 2'' - 24''
Max. permissible pressure
106 bar / 1500 PSI
Min. permissible temperature
0 °C / 32 °F
Max. permissible temperature
816 °C / 1500 °F
Temperatures < 0 °C on request
Selection as per pressure/temperature ratings
(
ð
Section 4.7.1.4, Page 65)
4.7.1.2 Fluids handled
▪
Steam
▪
Fluids containing gas
▪
Gas
▪
High-temperature hot water
▪
Volatile fluids
▪
Feed water
4.7.1.3 Design details
Design
▪
Swing check valve to BS 1868
▪
Tested to API 598
▪
Body made of cast steel or stainless steel
▪
Bolted cover
▪
Internally mounted hinge pin up to 12''
▪
Externally mounted hinge pin for 14" and above
▪
Stainless steel/graphite gaskets
▪
Fully confined cover gasket
▪
Valve seat made of wear-resistant and corrosion-proof materials
▪
Disc protected against rotation
▪
Anti-rotation pin up to 12''
▪
Adjusting bolt up to 12''
▪
The valves satisfy the safety requirements of Annex I of the European Pressure
Equipment Directive 97/23/EC (PED) for fluids in Groups 1 and 2.
▪
The valves do not have a potential internal source of ignition and can be used in
potentially explosive atmospheres, Group II, category 2 (zones 1+21) and
category 3 (zones 2+22) to ATEX 2014/34/EU.