Figu
re 73 Calibration in mode S11
Connect the test equipment
(DUT)
to the
TEST
port of the measuring bridge and measure the reflec-
tion coefficient.
Note. The reflection coefficient
S11
will be displayed in a logarithmic grid with vertical axis in dB. The
horizontal axis displays the specified frequency range of the signal, figure 74.
igure 74 Graph of the reflection coefficient in a given frequency range
9.4. Measurement of standing wave ratio (SWR)
9.4.1. In the
Generator
menu, turn on the
Tracking
mode and set the value of the
Generator Power
in the range from -15 to -25 dBm, depending on the equipment under study. Set the desired attenuation
value of the input attenuator
Input attenuator