TECHNICAL DATA
8
73
WATERFLUX 3070
www.krohne.com
06/2016 - 4004999701 - MA WATERFLUX 3070 - R01 en
Installation conditions
Installation
Assure that flow sensor is always fully filled.
For detailed information refer to
Installation
on page 15.
Flow direction
Forward and reverse
Arrow on flow sensor indicates forward flow direction.
Inlet run
≥
0 DN
For detailed information refer to
Measurement accuracy
on page 85.
Outlet run
≥
0 DN
For detailed information refer to
Measurement accuracy
on page 85.
Dimensions and weights
For detailed information refer to
Dimensions and weights
on page 87.
Materials
Sensor housing
Sheet steel
Measuring tube
DN25...200: metallic alloy
DN250....600: stainless steel
Flanges
DN25...150 Stainless Steel 1.4404 (316L)
DN200 Stainless Steel 1.4301 (304L)
DN250...DN600 Steel St37-C22 / A105
Optional: DN250...DN600 Stainless Steel
Liner
Rilsan
®
Protective coating
On exterior of the meter: flanges, housing, and / or connection box (field
version)
Standard: coating
Option: subsoil coating
Measuring electrodes
Standard: stainless steel 1.4301 / AISI 304
Optional: Hastelloy
®
C
Reference electrode
Standard: stainless steel 1.4301 / AISI 304
Optional: Hastelloy
®
C
Grounding rings
Grounding rings can be omitted when the reference electrode is used.
Signal converter housing
Polycarbonate
Wall holder for
remote signal converter
Polycarbonate
Connection box
Only for remote versions.
Stainless steel