8
TECHNICAL DATA
70
WATERFLUX 3070
www.krohne.com
06/2016 - 4004999701 - MA WATERFLUX 3070 - R01 en
8.2 Technical data
INFORMATION!
•
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.
•
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Downloadcenter).
Measuring system
Measuring principle
Faraday's law of induction
Application range
Electrically conductive fluids
Measured value
Measured value
Measured value
Measured value
Primary measured value
Flow velocity
Secondary measured value
Volume flow
Optional measured value
Pressure and temperature
Design
Features
Unique rectangular flow tube design providing improved flow profile and
signal to noise ratio resulting in highest accuracy, low energy consumption
and large turndown ratio
Rilsan
®
polymer coated flow tube approved for drinking water
No internal or moving parts
Built-in reference electrode
Optional; built-in P&T sensor (restricted to DN50...200), refer to
Integrated
P&T sensor (optional)
on page 76
Self-providing energy by batteries for up to 10 years
Modular construction
The measurement system consists of a flow sensor and a signal converter.
It is available as a compact and as a remote version.
Compact version
With IFC 070 converter: WATERFLUX 3070 C
Remote version
In field (F) version with IFC 070 converter: WATERFLUX 3070 F
Cable length up to 25 m / 70 ft, other lengths on request
Nominal diameter
DN25...600 / 1...24", Rectangular bore
Display and user interface
Display and user interface
Display and user interface
Display and user interface
Display
LCD display, 8 digits
Operation
2 optical keys to navigate through the menu of the signal converter without
opening the housing.
Display information
Standard:
Standard:
Standard:
Standard:
Sum counter (default), forward counter, reverse counter or flow rate
Flow direction (forward or reverse), counter settings
Measured value and measuring unit
Battery lifetime indicator
Optional:
Operating pressure, operating temperature, empty pipe, self-test, display
test, test mode, diameter, meter constant, software version, AMR mode,
warning sign, multiplier
Remote reading
Optional: external GSM / GPRS data logger for pulse or Modbus
For preselected data logger brands, please contact KROHNE