8
TECHNICAL DATA
76
WATERFLUX 3070
www.krohne.com
06/2016 - 4004999701 - MA WATERFLUX 3070 - R01 en
8.3 Integrated P&T sensor (optional)
Design
Features
Optional: integrated pressure and temperature sensor in the
WATERFLUX 3000 sensor.
In combination with:
IFC 070 (compact and remote)
WATERFLUX 3000 sensor DN50...200
Measurements
Measuring range
Pressure
-0.5...16 bar / -7.3...232 psi (relative)
Temperature
-5...+70
°
C / +23...158
°
F
Measuring units
Pressure
Default setting: bar
Selectable: mbar, psi
Temperature
Default setting:
°
C
Selectable:
°
F
Measurement interval
Default setting: 15 min.
Selectable: 1m, 5m, 10m, 15m or equal to the measurement flow interval.
Measuring accuracy
Maximum measuring
accuracy
Pressure
±
1% of full scale ( 0,5 ...16 bar / -7.3...232 psi) mm/s
Temperature
±
1,5
°
C for -5
°
...+70
°
C / +23...158
°
F
Materials
Pressure and temperature
sensor
316L