ELECTRICAL CONNECTIONS
4
29
WATERFLUX 3070
www.krohne.com
06/2016 - 4004999701 - MA WATERFLUX 3070 - R01 en
4.4 Cable overview
The following overview describes the different cables available for the compact and remote
version
The sensor cable for the IP68 remote (field) version has an 8 pins male connector.
The I/O cable (pulse /modbus) is available in a KROHNE FlexPower version and has an additional
power cable connection.
Overview I/O cables, with or without a power cable, with female connector:
IP 68 Cable versions
Electrical values
•
Pulse output
Pulse output
Pulse output
Pulse output
2x Pulse output passive - ( maximum 3 outputs possible, see status output):
2x Pulse output passive - ( maximum 3 outputs possible, see status output):
2x Pulse output passive - ( maximum 3 outputs possible, see status output):
2x Pulse output passive - ( maximum 3 outputs possible, see status output):
f
≤
100 Hz; I
≤
10 mA; U: 2.7...24 VDC (P
≤
100 mW)
•
Status output
Status output
Status output
Status output
2x Status output passive - ( 1 status output can be used as a third pulse output):
2x Status output passive - ( 1 status output can be used as a third pulse output):
2x Status output passive - ( 1 status output can be used as a third pulse output):
2x Status output passive - ( 1 status output can be used as a third pulse output):
I
≤
10 mA; U: 2.7...24 VDC (P
≤
100 mW)
•
Communication
Communication
Communication
Communication
Modbus RTU output - (detailed information available in Supplementary Manual)
•
Optional:
Optional:
Optional:
Optional:
KGA external data logger / GSM module - (see the KGA 42 Supplementary Manual)
I/O version
KROHNE FlexPower cable
PIN
Modbus cable
N
4
Pulse cable
N
8
KGA 42
N
8
Modbus cable
Y
10
Pulse cable
Y
8
KGA 42
Y
8