Installation
In the inverter, “Storage of excess AC energy from local
generation” must be activated by going to Service menu
> Energy management.
If changes are to be made to the settings, perform the
following steps:
1.
Call up online interface of KOSTAL Smart Energy
Meter
2.
Call up Modbus configuration under Modbus
settings.
3.
Select PIKO IQ/ PLENTICORE from drop-down
list.
Parameter
Value
Interface
RS485 A
Active slave
Yes
Presetting
PIKO IQ/PLENTICORE
Slave address
1
Baud rate
38400
Data bits
8
Parity
None
Stop bit
2
4.
Press “Save” button to accept settings.
5.
In the inverter, activate “Storage of excess AC energy
from local generation” by going to Service menu >
Energy management.
H
The inverter has been set up.
INFO
For details, refer to the inverter’s
operating manual. Setting on inverter
only possible after logging in as an
installer.
INFO
When an inverter is selected, the pre-
defined default values are adopted.
These can be adapted if necessary.
INFO
For details, refer to the inverter’s
operating manual. Setting on inverter
only possible after logging in as an
installer.