Kongsberg EM 710
10.2.9 Ethernet cable with RJ45
This cable is used to provide standard Ethernet connections. Note
that various categories exists.
Cat.5 E
and
Cat.6
cables are used
in local area networks with date rate exceeding 100 Mbit/s.
Ethernet cables are available commercially in different lengths,
colours and categories.
Pairs
RJ45 plug
RJ45 plug
Ethernet 10Base-T
“
Straight Through
”
Ethernet 10Base-T
“
Crossover
”
The
“
crossover
”
cable is used to cascade HUBs,
or for connecting two ethernet stations or
computers back-to-back without a HUB)
(1)
TX Data + to (3) Recv Data +
(2) Tx Data - to (6) Recv Data -
(3) Recv Data + to (1)
Tx Data +
(6) Recv Data - to (2)
Tx Data -
Pin 8
Pin 1
View
Pin 1
Pin 8
End view
of RJ45 plug
1
3
2
4
5
7
6
8
1
3
2
4
5
7
6
8
W400
Rev.F
Ethernet 10Base-T
with RJ45 plugs
Screened category 6 (or 5 E) twisted pair cable to fit the specific
RJ45 connectors used. AWG 23 and 24 size conductors are
recommended.
142
164851/C
Summary of Contents for EM 710
Page 1: ...Installation Manual EM 710 Multibeam echo sounder ...
Page 2: ......
Page 44: ...Kongsberg EM 710 Figure 10 Transducer mounting principles 42 164851 C ...
Page 63: ...Cable layout Figure 20 Transceiver Unit front view 0 5 x 1 degree 164851 C 61 ...
Page 88: ...Kongsberg EM 710 Figure 42 Cable clamp Transceiver Unit cable clamp on page 133 86 164851 C ...
Page 113: ...Installation drawings 164851 C 111 ...
Page 114: ...Kongsberg EM 710 10 1 2 1 mounting frame assembly RX module 112 164851 C ...
Page 115: ...Installation drawings 164851 C 113 ...
Page 116: ...Kongsberg EM 710 10 1 3 2 mounting frame assembly TX RX module 114 164851 C ...
Page 117: ...Installation drawings 164851 C 115 ...
Page 118: ...Kongsberg EM 710 10 1 4 0 5 x 1 gondola 116 164851 C ...
Page 119: ...Installation drawings 164851 C 117 ...
Page 120: ...Kongsberg EM 710 10 1 5 Transducer TX1 Outline dimensions 118 164851 C ...
Page 121: ...Installation drawings 164851 C 119 ...
Page 122: ...Kongsberg EM 710 10 1 6 Transducer TX2 Outline dimensions 120 164851 C ...
Page 123: ...Installation drawings 164851 C 121 ...
Page 124: ...Kongsberg EM 710 10 1 7 Transducer RX1 Outline dimensions 122 164851 C ...
Page 125: ...Installation drawings 164851 C 123 ...
Page 126: ...Kongsberg EM 710 10 1 8 Transducer RX2 Outline dimensions 124 164851 C ...
Page 127: ...Installation drawings 164851 C 125 ...
Page 128: ...Kongsberg EM 710 10 1 9 HWS Operator Station Outline dimensions 126 164851 C ...
Page 129: ...Installation drawings 10 1 10 Transceiver Unit Outline dimensions 164851 C 127 ...
Page 130: ...Kongsberg EM 710 128 164851 C ...
Page 132: ...Kongsberg EM 710 130 164851 C ...
Page 133: ...Installation drawings 10 1 12 Transceiver Unit mounting bracket 164851 C 131 ...
Page 134: ...Kongsberg EM 710 10 1 13 Junction Box outline dimensions 132 164851 C ...
Page 135: ...Installation drawings 10 1 14 Transceiver Unit cable clamp 164851 C 133 ...