Kongsberg EM 710
6 SYSTEM UNITS
Topics
•
on page 48
•
on page 48
•
on page 54
This chapter describes the installation of the EM 710 Transceiver
Unit in the equipment or operation room, and the Operator
Station in the operation room.
The Remote Control Junction Box installation is also described.
Drawings showing the system and the physical dimensions are
included in the text.
Note
Kongsberg Maritime strongly recommends that an
Uninterruptible Power Supply (UPS) is used to power the
Operator Station.
6.1 Operator station
The EM 710 Operator Station consists of a Kongsberg PC based
work station. Main units are computer chassis, display monitor,
keyboard, mouse, units for external data storage.
Location
It is recommended to place the Operator Station in a room with
environmental conditions similar to those required for extended
human occupation. The Operator Station is usually mounted in
the operation room, in a rack.
Installation
No specific installation procedures exist for the Operator Station.
However, you must install the units so that they are properly
physically supported and protected for shock and vibration due
to sea conditions.
6.2 Transceiver Unit
This chapter presents the general installation procedures for the
EM710 Transceiver Unit.
The Transceiver Unit contains all transmit and receive
electronics. It comprises one or two 19” sub-racks contained in a
cabinet designed for bulkhead or deck mounting.
48
164851/C
Summary of Contents for EM 710
Page 1: ...Installation Manual EM 710 Multibeam echo sounder ...
Page 2: ......
Page 44: ...Kongsberg EM 710 Figure 10 Transducer mounting principles 42 164851 C ...
Page 63: ...Cable layout Figure 20 Transceiver Unit front view 0 5 x 1 degree 164851 C 61 ...
Page 88: ...Kongsberg EM 710 Figure 42 Cable clamp Transceiver Unit cable clamp on page 133 86 164851 C ...
Page 113: ...Installation drawings 164851 C 111 ...
Page 114: ...Kongsberg EM 710 10 1 2 1 mounting frame assembly RX module 112 164851 C ...
Page 115: ...Installation drawings 164851 C 113 ...
Page 116: ...Kongsberg EM 710 10 1 3 2 mounting frame assembly TX RX module 114 164851 C ...
Page 117: ...Installation drawings 164851 C 115 ...
Page 118: ...Kongsberg EM 710 10 1 4 0 5 x 1 gondola 116 164851 C ...
Page 119: ...Installation drawings 164851 C 117 ...
Page 120: ...Kongsberg EM 710 10 1 5 Transducer TX1 Outline dimensions 118 164851 C ...
Page 121: ...Installation drawings 164851 C 119 ...
Page 122: ...Kongsberg EM 710 10 1 6 Transducer TX2 Outline dimensions 120 164851 C ...
Page 123: ...Installation drawings 164851 C 121 ...
Page 124: ...Kongsberg EM 710 10 1 7 Transducer RX1 Outline dimensions 122 164851 C ...
Page 125: ...Installation drawings 164851 C 123 ...
Page 126: ...Kongsberg EM 710 10 1 8 Transducer RX2 Outline dimensions 124 164851 C ...
Page 127: ...Installation drawings 164851 C 125 ...
Page 128: ...Kongsberg EM 710 10 1 9 HWS Operator Station Outline dimensions 126 164851 C ...
Page 129: ...Installation drawings 10 1 10 Transceiver Unit Outline dimensions 164851 C 127 ...
Page 130: ...Kongsberg EM 710 128 164851 C ...
Page 132: ...Kongsberg EM 710 130 164851 C ...
Page 133: ...Installation drawings 10 1 12 Transceiver Unit mounting bracket 164851 C 131 ...
Page 134: ...Kongsberg EM 710 10 1 13 Junction Box outline dimensions 132 164851 C ...
Page 135: ...Installation drawings 10 1 14 Transceiver Unit cable clamp 164851 C 133 ...