Kongsberg EM 710
9.2 Electrical checks
9.2.1 Scope
This section of the manual contains the test procedures for the
EM 710 system’s power and signal interface cables.
WARNING
These checks must be completed before any power
is switched onto the system.
9.2.2 Cabling
Visual cable inspection
Refer to the cable plans and interconnection diagrams, and
check all power and interconnection cables. Any locally fitted
plugs and connectors should also be checked to ensure that the
correct types have been used for the specific locations. (Sealed
or spark-proof connectors in areas where flammable gasses may
accumulate, etc.)
Ensure that all cable connections have been made according to the
cable plan, and that all connections are tight and secure. Ensure
that all cables are correctly laid in conduits, or are otherwise
protected according to the regulations and recommendations laid
down by the vessel’s registering authority. Ensure all protective
covers are fastened correctly.
Cable connections and continuity
After the cable connections have been completed and the
visual inspection has been carried out, all the cable cores must
be checked for correct connection and continuity. Refer to
the cable plans and interconnection diagrams, and check all
interconnection cables. Any locally fitted plugs and connectors
must be checked for shorts or open circuits. Ensure all cable
connections have been made according to the cable plan, and that
all connections are tight and secure.
The check procedure will require two engineers equipped with
two-way communication devices; one will require continuity test
equipment, while the other will require a suitable shorting strap.
Follow the check procedure below for each cable core
1
Position yourselves one at each end of the cable to be
checked. Good communications must be established
between you and your assistant.
2
Ensure that the cable to be tested is not connected to any
power source.
106
164851/C
Summary of Contents for EM 710
Page 1: ...Installation Manual EM 710 Multibeam echo sounder ...
Page 2: ......
Page 44: ...Kongsberg EM 710 Figure 10 Transducer mounting principles 42 164851 C ...
Page 63: ...Cable layout Figure 20 Transceiver Unit front view 0 5 x 1 degree 164851 C 61 ...
Page 88: ...Kongsberg EM 710 Figure 42 Cable clamp Transceiver Unit cable clamp on page 133 86 164851 C ...
Page 113: ...Installation drawings 164851 C 111 ...
Page 114: ...Kongsberg EM 710 10 1 2 1 mounting frame assembly RX module 112 164851 C ...
Page 115: ...Installation drawings 164851 C 113 ...
Page 116: ...Kongsberg EM 710 10 1 3 2 mounting frame assembly TX RX module 114 164851 C ...
Page 117: ...Installation drawings 164851 C 115 ...
Page 118: ...Kongsberg EM 710 10 1 4 0 5 x 1 gondola 116 164851 C ...
Page 119: ...Installation drawings 164851 C 117 ...
Page 120: ...Kongsberg EM 710 10 1 5 Transducer TX1 Outline dimensions 118 164851 C ...
Page 121: ...Installation drawings 164851 C 119 ...
Page 122: ...Kongsberg EM 710 10 1 6 Transducer TX2 Outline dimensions 120 164851 C ...
Page 123: ...Installation drawings 164851 C 121 ...
Page 124: ...Kongsberg EM 710 10 1 7 Transducer RX1 Outline dimensions 122 164851 C ...
Page 125: ...Installation drawings 164851 C 123 ...
Page 126: ...Kongsberg EM 710 10 1 8 Transducer RX2 Outline dimensions 124 164851 C ...
Page 127: ...Installation drawings 164851 C 125 ...
Page 128: ...Kongsberg EM 710 10 1 9 HWS Operator Station Outline dimensions 126 164851 C ...
Page 129: ...Installation drawings 10 1 10 Transceiver Unit Outline dimensions 164851 C 127 ...
Page 130: ...Kongsberg EM 710 128 164851 C ...
Page 132: ...Kongsberg EM 710 130 164851 C ...
Page 133: ...Installation drawings 10 1 12 Transceiver Unit mounting bracket 164851 C 131 ...
Page 134: ...Kongsberg EM 710 10 1 13 Junction Box outline dimensions 132 164851 C ...
Page 135: ...Installation drawings 10 1 14 Transceiver Unit cable clamp 164851 C 133 ...