Kongsberg EM 710
10.2.7 Remote control and external trig
This cable connects the EM 710 Transceiver Unit to a remote
On/Off switch, normally located in a Remote Control junction
box.
The same connection allows trigger output and remote control
(synchronization) with a serial line.
W245 / Rev . A
NSEM Remote On/Of f control and synchronization
1
3
2
4
5
7
6
8
9
9
9
1
1
3
3
2
2
4
4
5
5
7
7
6
6
8
8
Junction box
Terminal block
Trigger out (TRIG OUT)
TRIG OUT
Trigger ground (TRIG GND)
TRIG GND
S (+24V)
Standby - (24V GND)
On (ON)
Ready to send / blanking (R
TS)
GND
Trig in (CTS)
RTS
Ground (GND)
CTS
Not connected (NC)
Local 9-pin
‘
D
’
connector
Trigger out to
external system
(synchronization)
Serial line to/from
external system (synchronization)
Junction box
System On/Of f
• Conductors: 5 x 2 x 0.5 mm²
• Screen: Overall braided
• Voltage: 60 V
• Maximum diameter: Limited by the plugs
140
164851/C
Summary of Contents for EM 710
Page 1: ...Installation Manual EM 710 Multibeam echo sounder ...
Page 2: ......
Page 44: ...Kongsberg EM 710 Figure 10 Transducer mounting principles 42 164851 C ...
Page 63: ...Cable layout Figure 20 Transceiver Unit front view 0 5 x 1 degree 164851 C 61 ...
Page 88: ...Kongsberg EM 710 Figure 42 Cable clamp Transceiver Unit cable clamp on page 133 86 164851 C ...
Page 113: ...Installation drawings 164851 C 111 ...
Page 114: ...Kongsberg EM 710 10 1 2 1 mounting frame assembly RX module 112 164851 C ...
Page 115: ...Installation drawings 164851 C 113 ...
Page 116: ...Kongsberg EM 710 10 1 3 2 mounting frame assembly TX RX module 114 164851 C ...
Page 117: ...Installation drawings 164851 C 115 ...
Page 118: ...Kongsberg EM 710 10 1 4 0 5 x 1 gondola 116 164851 C ...
Page 119: ...Installation drawings 164851 C 117 ...
Page 120: ...Kongsberg EM 710 10 1 5 Transducer TX1 Outline dimensions 118 164851 C ...
Page 121: ...Installation drawings 164851 C 119 ...
Page 122: ...Kongsberg EM 710 10 1 6 Transducer TX2 Outline dimensions 120 164851 C ...
Page 123: ...Installation drawings 164851 C 121 ...
Page 124: ...Kongsberg EM 710 10 1 7 Transducer RX1 Outline dimensions 122 164851 C ...
Page 125: ...Installation drawings 164851 C 123 ...
Page 126: ...Kongsberg EM 710 10 1 8 Transducer RX2 Outline dimensions 124 164851 C ...
Page 127: ...Installation drawings 164851 C 125 ...
Page 128: ...Kongsberg EM 710 10 1 9 HWS Operator Station Outline dimensions 126 164851 C ...
Page 129: ...Installation drawings 10 1 10 Transceiver Unit Outline dimensions 164851 C 127 ...
Page 130: ...Kongsberg EM 710 128 164851 C ...
Page 132: ...Kongsberg EM 710 130 164851 C ...
Page 133: ...Installation drawings 10 1 12 Transceiver Unit mounting bracket 164851 C 131 ...
Page 134: ...Kongsberg EM 710 10 1 13 Junction Box outline dimensions 132 164851 C ...
Page 135: ...Installation drawings 10 1 14 Transceiver Unit cable clamp 164851 C 133 ...