Kongsberg EM 710
4 TRANSDUCER ARRAYS
This chapter describes the installation of the EM 710 Transmit
(TX) and Receive (RX) Transducer Arrays.
Drawings showing the installation principles and the physical
dimensions are included in the text. Other drawings are included
in the Drawing File.
Topics
•
on page 26
•
on page 27
•
on page 31
•
on page 36
•
Installing the mounting frames
on page 38
•
Installing the transducer modules
on page 39
4.1 Installation principles
4.1.1 Basic description
The EM 710 uses separate transducer arrays for transmitting and
receiving sound pulses.
The transducers may be fixed to the hull with bolts from the front,
either directly on or recessed into the hull, or within sea chests.
The two transducer arrays are normally mounted as “T” or
“L”-configurations, or a similar variant under the vessel’s hull
(Mills Cross configuration).
The transmit transducer array should be approximately aligned
parallel to the vessel’s keel. The receiver transducer array should
be approximately aligned 90º on the keel. Both transducers
should be horizontal, approximately on a plane on the keel.
There is no need for the arrays to have the exact same heading,
roll and pitch.
The number of individual Tx and Rx modules in the two arrays
depends on the chosen EM 710 configuration.
System configuration
TX modules
RX modules
0.5 x 1 degree
2 x TX1
1 x RX1
1 x 1 degree
1 x TX1
1 x RX1
1 x 2 degree
1 x TX1
1 x RX2
2 x 2 degree
1 x TX2
1 x RX2
The cables connecting the transducers to the Transceiver
Unit have a standard length of 15 m, and are terminated with
connectors which plug directly into the cabinet.
26
164851/C
Summary of Contents for EM 710
Page 1: ...Installation Manual EM 710 Multibeam echo sounder ...
Page 2: ......
Page 44: ...Kongsberg EM 710 Figure 10 Transducer mounting principles 42 164851 C ...
Page 63: ...Cable layout Figure 20 Transceiver Unit front view 0 5 x 1 degree 164851 C 61 ...
Page 88: ...Kongsberg EM 710 Figure 42 Cable clamp Transceiver Unit cable clamp on page 133 86 164851 C ...
Page 113: ...Installation drawings 164851 C 111 ...
Page 114: ...Kongsberg EM 710 10 1 2 1 mounting frame assembly RX module 112 164851 C ...
Page 115: ...Installation drawings 164851 C 113 ...
Page 116: ...Kongsberg EM 710 10 1 3 2 mounting frame assembly TX RX module 114 164851 C ...
Page 117: ...Installation drawings 164851 C 115 ...
Page 118: ...Kongsberg EM 710 10 1 4 0 5 x 1 gondola 116 164851 C ...
Page 119: ...Installation drawings 164851 C 117 ...
Page 120: ...Kongsberg EM 710 10 1 5 Transducer TX1 Outline dimensions 118 164851 C ...
Page 121: ...Installation drawings 164851 C 119 ...
Page 122: ...Kongsberg EM 710 10 1 6 Transducer TX2 Outline dimensions 120 164851 C ...
Page 123: ...Installation drawings 164851 C 121 ...
Page 124: ...Kongsberg EM 710 10 1 7 Transducer RX1 Outline dimensions 122 164851 C ...
Page 125: ...Installation drawings 164851 C 123 ...
Page 126: ...Kongsberg EM 710 10 1 8 Transducer RX2 Outline dimensions 124 164851 C ...
Page 127: ...Installation drawings 164851 C 125 ...
Page 128: ...Kongsberg EM 710 10 1 9 HWS Operator Station Outline dimensions 126 164851 C ...
Page 129: ...Installation drawings 10 1 10 Transceiver Unit Outline dimensions 164851 C 127 ...
Page 130: ...Kongsberg EM 710 128 164851 C ...
Page 132: ...Kongsberg EM 710 130 164851 C ...
Page 133: ...Installation drawings 10 1 12 Transceiver Unit mounting bracket 164851 C 131 ...
Page 134: ...Kongsberg EM 710 10 1 13 Junction Box outline dimensions 132 164851 C ...
Page 135: ...Installation drawings 10 1 14 Transceiver Unit cable clamp 164851 C 133 ...