Transducer arrays
2
Alter the drawings and the design as required to fit the vessel
and the chosen installation method.
3
Mount the casings in the blister or integrated into the hull.
4
The mounting frames must be bolted onto the flat bars inside
the casing.
The number of flat bars depends on the length of the array.
Note
The mounting frames must be installed with correct
orientation!
5
The mounting frames must be bolted properly to the bars.
The frames are fastened by M12 hex cap screws. Use a
torque of approximately 74 Nm.
6
Check that the frames are mounted completely flat.
No point on the frames may deviate from the horizontal
plane with more than ± 0.2 mm.
Refer
on page 96 chapter for a proposed
measuring method.
7
Repeat the previous step until the alignment procedure has
been performed successfully.
4.5.3 Installation accuracy of frames
Check that the frames are mounted completely flat. This is very
important for the calibration of the system and the results of the
data information in SIS.
No point on the frames may deviate from the horizontal plane
with more than
± 0.2 mm
. This is very important to follow.
4.6 Installing the transducer modules
To make the installation of the transducers easier, they are built
with standard modules
1
TX modules (type TX1 or TX2)
2
RX modules (type RX1 or RX2)
The two transducer module types are identified by their unique
registration numbers, which are moulded into the rear of the
element.
The transducer modules are assembled in the mounting frames
especially designed for this purpose. The modules are secured
with steel brackets, while the cables are pulled out on the side
of each array.
164851/C
39
Summary of Contents for EM 710
Page 1: ...Installation Manual EM 710 Multibeam echo sounder ...
Page 2: ......
Page 44: ...Kongsberg EM 710 Figure 10 Transducer mounting principles 42 164851 C ...
Page 63: ...Cable layout Figure 20 Transceiver Unit front view 0 5 x 1 degree 164851 C 61 ...
Page 88: ...Kongsberg EM 710 Figure 42 Cable clamp Transceiver Unit cable clamp on page 133 86 164851 C ...
Page 113: ...Installation drawings 164851 C 111 ...
Page 114: ...Kongsberg EM 710 10 1 2 1 mounting frame assembly RX module 112 164851 C ...
Page 115: ...Installation drawings 164851 C 113 ...
Page 116: ...Kongsberg EM 710 10 1 3 2 mounting frame assembly TX RX module 114 164851 C ...
Page 117: ...Installation drawings 164851 C 115 ...
Page 118: ...Kongsberg EM 710 10 1 4 0 5 x 1 gondola 116 164851 C ...
Page 119: ...Installation drawings 164851 C 117 ...
Page 120: ...Kongsberg EM 710 10 1 5 Transducer TX1 Outline dimensions 118 164851 C ...
Page 121: ...Installation drawings 164851 C 119 ...
Page 122: ...Kongsberg EM 710 10 1 6 Transducer TX2 Outline dimensions 120 164851 C ...
Page 123: ...Installation drawings 164851 C 121 ...
Page 124: ...Kongsberg EM 710 10 1 7 Transducer RX1 Outline dimensions 122 164851 C ...
Page 125: ...Installation drawings 164851 C 123 ...
Page 126: ...Kongsberg EM 710 10 1 8 Transducer RX2 Outline dimensions 124 164851 C ...
Page 127: ...Installation drawings 164851 C 125 ...
Page 128: ...Kongsberg EM 710 10 1 9 HWS Operator Station Outline dimensions 126 164851 C ...
Page 129: ...Installation drawings 10 1 10 Transceiver Unit Outline dimensions 164851 C 127 ...
Page 130: ...Kongsberg EM 710 128 164851 C ...
Page 132: ...Kongsberg EM 710 130 164851 C ...
Page 133: ...Installation drawings 10 1 12 Transceiver Unit mounting bracket 164851 C 131 ...
Page 134: ...Kongsberg EM 710 10 1 13 Junction Box outline dimensions 132 164851 C ...
Page 135: ...Installation drawings 10 1 14 Transceiver Unit cable clamp 164851 C 133 ...