2-44
PC290-ENG
CHECK AIR CLEANER FOR CLOGGING
1.
Confirm that the air cleaner clogging monitor does not flash
2.
If it flashes, immediately clean or replace the element.
For details of the method of cleaning the element, see 24.2.1
“CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT”.
CHECK ELECTRIC WIRING
WARNING
If the fuse blows frequently, or there are traces of short-
circuiting in the electric wiring, always locate and repair the
cause.
Check for damage of the fuse and any sign of disconnection or short
circuit in the electric wiring. Check also for loose terminals and tighten
any loose parts. Check the following points carefully.
•
Battery
•
Starting motor
•
Alternator
Please contact your Komatsu distributor for investigation and correc-
tion of the cause.
CHECK FOR WATER AND SEDIMENT IN WATER SEPARATOR.
Drain water & sediment
A fuel sedimentor is mounted in pump compartment. Entrapped sedi-
ment & water can be seen trough the glass bowl.
1.
Loose drain plug
y
and drain water and sediment until none visible
in bowl.
2.
Tighten drain plug.
A
Fuel
B
Water/Sediment
12. OPERATION
A
B
BP00100
Summary of Contents for PC290LC-6K
Page 2: ......
Page 44: ...1 32 PC290 ENG MEMO ...
Page 45: ...2 1 PC290 ENG OPERATION ...
Page 146: ...2 102 PC290 ENG MEMO ...
Page 147: ...3 1 PC290 ENG MAINTENANCE ...
Page 171: ...3 25 PC290 ENG 22 PERIODIC REPLACEMENT OF SAFETY CRITICAL PARTS m n ...
Page 223: ...4 1 PC290 ENG SPECIFICATIONS ...
Page 225: ...4 3 PC290 ENG 25 SPECIFICATIONS PC290LC 6K ...
Page 226: ...4 4 PC290 ENG 25 SPECIFICATIONS PC290NLC 6K ...
Page 230: ...4 8 PC290 ENG 25 SPECIFICATIONS Mono Boom ...
Page 233: ...5 1 PC29 ENG OPTIONS ATTACHMENTS ...
Page 264: ...5 30 PC29 ENG MEMO ...