1-12
PC290-ENG
WARNING: For reasons of safety, al-
ways follow these safety precautions.
PROHIBITED OPERATIONS
• Do not dig the work face under an overhang. This may cause the overhang to collapse and fall on top of the
machine.
• Do not carry out deep digging under the front of the machine. The ground under the machine may collapse
and cause the machine to fall.
DO NOT GO CLOSE TO HIGH-VOLTAGE CABLES
• Going close to high-voltage cables can cause electric shock. Always maintain the safe distance given below
between the machine and the electric cable.
• The following actions are effective in preventing accidents.
1) Wear shoes with rubber of leather soles.
2) Use a signalman to give warning if the machine approaches too close to the electric cable.
• If the work equipment should touch the electric cable, the operator should not leave the operator’s compart-
ment.
• When carrying out operations near high voltage cables, do not let anyone come close to the machine.
• Check with the electricity company about the voltage of the cables before starting operations.
Voltage Min. safety
distance
6.6 kV
3 m
10 ft
33.0 kV
4 m
14 ft
66.0 kV
5 m
17 ft
154.0 kV
8 m
27 ft
275.0 kV
10 m
33 ft
7. PRECAUTIONS DURING OPERATION
Summary of Contents for PC290LC-6K
Page 2: ......
Page 44: ...1 32 PC290 ENG MEMO ...
Page 45: ...2 1 PC290 ENG OPERATION ...
Page 146: ...2 102 PC290 ENG MEMO ...
Page 147: ...3 1 PC290 ENG MAINTENANCE ...
Page 171: ...3 25 PC290 ENG 22 PERIODIC REPLACEMENT OF SAFETY CRITICAL PARTS m n ...
Page 223: ...4 1 PC290 ENG SPECIFICATIONS ...
Page 225: ...4 3 PC290 ENG 25 SPECIFICATIONS PC290LC 6K ...
Page 226: ...4 4 PC290 ENG 25 SPECIFICATIONS PC290NLC 6K ...
Page 230: ...4 8 PC290 ENG 25 SPECIFICATIONS Mono Boom ...
Page 233: ...5 1 PC29 ENG OPTIONS ATTACHMENTS ...
Page 264: ...5 30 PC29 ENG MEMO ...