3-31
PC290-ENG
4)
If small holes or thinner parts are found on the element when it is
checked with an electric bulb after cleaning, replace the element
NOTICE
Do not use an element whose folds or gasket or seal are
damaged.
When cleaning the element, do not hit it or beat it against
something.
5.
Remove the cloth and tape used for cover in Step 1.
6.
Install the cleaned element and fix it with the wing nut.
7.
Replace the seal washer
v
or the wing nut
x
with new parts if they
are broken.
8.
Remove the evacuator valve
b
and clean it with compressed air.
After cleaning, install it.
Replacing the inner element
1.
Firsts remove the cover and the outer element, and then remove the
inner element.
2.
To prevent dust from getting in, use a clean cloth or tape to cover the
air connector (outlet side).
3.
Clean the air cleaner body interior, then remove the cover installed in
Step 2.
4.
Fit a new inner element to the connector and tighten it with the nuts.
Do not clean and reinstall an inner element.
5.
Install the outer element and fix it with the wing nut.
24. SERVICE PROCEDURE
Summary of Contents for PC290LC-6K
Page 2: ......
Page 44: ...1 32 PC290 ENG MEMO ...
Page 45: ...2 1 PC290 ENG OPERATION ...
Page 146: ...2 102 PC290 ENG MEMO ...
Page 147: ...3 1 PC290 ENG MAINTENANCE ...
Page 171: ...3 25 PC290 ENG 22 PERIODIC REPLACEMENT OF SAFETY CRITICAL PARTS m n ...
Page 223: ...4 1 PC290 ENG SPECIFICATIONS ...
Page 225: ...4 3 PC290 ENG 25 SPECIFICATIONS PC290LC 6K ...
Page 226: ...4 4 PC290 ENG 25 SPECIFICATIONS PC290NLC 6K ...
Page 230: ...4 8 PC290 ENG 25 SPECIFICATIONS Mono Boom ...
Page 233: ...5 1 PC29 ENG OPTIONS ATTACHMENTS ...
Page 264: ...5 30 PC29 ENG MEMO ...