2-44
PC210/240-ENG
CHECK AIR CLEANER FOR CLOGGING
1.
Confirm that the air cleaner clogging monitor does not flash
2.
If it flashes, immediately clean or replace the element.
For details of the method of cleaning the element, see 24.2.1
“CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT”.
CHECK ELECTRIC WIRING
WARNING
If the fuse blows frequently, or there are traces of short-
circuiting in the electric wiring, always locate and repair the
cause.
Check for damage of the fuse and any sign of disconnection or short
circuit in the electric wiring. Check also for loose terminals and tighten
any loose parts. Check the following points carefully.
•
Battery
•
Starting motor
•
Alternator
Please contact your Komatsu distributor for investigation and correc-
tion of the cause.
CHECK FOR WATER AND SEDIMENT IN WATER SEPARATOR.
Drain water & sediment
A fuel sedimentor is mounted in pump compartment. Entrapped sedi-
ment & water can be seen trough the glass bowl.
1.
Loose drain plug
y
and drain water and sediment until none visible
in bowl.
2.
Tighten drain plug.
A
Fuel
B
Water/Sediment
CHECK FOR WATER IN PRIMARY FUEL FILTER, DRAIN WATER
A primary fuel filter is fitted on the engine.
Drain the water from the primary seperator by turning cap at the
bottom of the filter.
12. OPERATION
A
B
H/O G/O F/O L/O B/O
Summary of Contents for PC210
Page 2: ......
Page 44: ...1 32 PC210 240 ENG MEMO ...
Page 45: ...2 1 PC210 240 ENG OPERATION ...
Page 146: ...2 102 PC210 240 ENG ...
Page 147: ...3 1 PC210 240 ENG MAINTENANCE ...
Page 167: ...3 21 PC210 240 ENG 22 PERIODIC REPLACEMENT OF SAFETY CRITICAL PARTS m n ...
Page 220: ...3 74 PC210 240 ENG ...
Page 221: ...4 1 PC210 240 ENG SPECIFICATIONS ...
Page 231: ...4 11 PC210 240 ENG 25 SPECIFICATIONS ...
Page 232: ...4 12 PC210 240 ENG ...
Page 233: ...5 1 PC210 240 ENG OPTIONS ATTACHMENTS ...
Page 266: ...5 34 PC210 240 ENG 5 32 ...