2-95
PC210/240-ENG
Connecting the booster cables
Keep the starting switch at the OFF position.
Connect the booster cable as follows, in the order of the numbers
marked in the diagram.
1.
Make sure that the starting switches of the normal machine and
problem machine are both at the OFF position.
2.
Connect one clip of booster cable
A
to the positive (+) terminal of
the problem machine.
3.
Connect the other clip of booster cable
B
to the positive (+) terminal
of the normal machine.
4.
Connect one clip of booster cable
B
to the negative (-) terminal of
the normal machine.
5.
Connect the other clip of booster cable
B
to the engine block of the
problem machine.
Starting the engine
1.
Make sure the clips are firmly connected to the battery terminals.
2.
Start the engine of the normal machine and keep it to run at high
idling speed.
3.
Turn the starting switch of the problem machine to the START posi-
tion and start the engine. If the engine doesn’t start at first, try again
after 2 minutes or so.
16. TROUBLESHOOTING
Summary of Contents for PC210
Page 2: ......
Page 44: ...1 32 PC210 240 ENG MEMO ...
Page 45: ...2 1 PC210 240 ENG OPERATION ...
Page 146: ...2 102 PC210 240 ENG ...
Page 147: ...3 1 PC210 240 ENG MAINTENANCE ...
Page 167: ...3 21 PC210 240 ENG 22 PERIODIC REPLACEMENT OF SAFETY CRITICAL PARTS m n ...
Page 220: ...3 74 PC210 240 ENG ...
Page 221: ...4 1 PC210 240 ENG SPECIFICATIONS ...
Page 231: ...4 11 PC210 240 ENG 25 SPECIFICATIONS ...
Page 232: ...4 12 PC210 240 ENG ...
Page 233: ...5 1 PC210 240 ENG OPTIONS ATTACHMENTS ...
Page 266: ...5 34 PC210 240 ENG 5 32 ...