3-26
PC210/240-ENG
24.2
WHEN REQUIRED
24.2.1 CHECK, CLEAN AND REPLACE THE AIR
CLEANER ELEMENT
Checking
If air cleaner clogging monitor
y
flashes, clean the air cleaner element.
Cleaning or replacing the outer element
1.
Open the front door on the left side of the machine, remove wing nut
x
and take out element
c
.
To prevent entry of dirt and dust, cover the air connector side of the
rear end of the air cleaner with a clean cloth and adhesive tape.
2.
Clean interior of the air cleaner body interior and the cover.
3.
Direct dry compressed air (less than 700 kPa (7 kg/cm
2
, 100 psi)), to
element
c
from inside along its folds, then direct it from outside
along its folds and again from inside.
1)
Replace the outer element if it has been cleaned 6 times repeatedly
or used throughout a year. Replace the inner element at the same
time.
2)
Replace both inner and outer elements when the monitor lamp
y
start flashing soon after installing the cleaned outer element even
though it may not have been cleaned 6 times.
3)
Check inner element mounting nuts for looseness and , if necessary,
retighten.
WARNING
• Never clean or replace the air cleaner element with the
engine running.
• When using pressured air to clean the element, wear
safety glasses or goggles to protect the eyes.
a
24. SERVICE PROCEDURE
Summary of Contents for PC210
Page 2: ......
Page 44: ...1 32 PC210 240 ENG MEMO ...
Page 45: ...2 1 PC210 240 ENG OPERATION ...
Page 146: ...2 102 PC210 240 ENG ...
Page 147: ...3 1 PC210 240 ENG MAINTENANCE ...
Page 167: ...3 21 PC210 240 ENG 22 PERIODIC REPLACEMENT OF SAFETY CRITICAL PARTS m n ...
Page 220: ...3 74 PC210 240 ENG ...
Page 221: ...4 1 PC210 240 ENG SPECIFICATIONS ...
Page 231: ...4 11 PC210 240 ENG 25 SPECIFICATIONS ...
Page 232: ...4 12 PC210 240 ENG ...
Page 233: ...5 1 PC210 240 ENG OPTIONS ATTACHMENTS ...
Page 266: ...5 34 PC210 240 ENG 5 32 ...