MAINTENANCE PROCEDURES
210
5.
Slightly strike the filtering element (4) on the palm of your
hand, in such a way as to remove the dust, and blow
compressed air on the inner surface, keeping the air jet at a
distance of approximately 15 cm and the pressure below 4-5
bars.
6.
After the cleaning operations, inspect the filtering surface for
damage by introducing a lamp into it and carefully check the
front gaskets. If the cartridge is damaged, change it.
7.
Remove the cloth or adhesive tape used to cover the air
connector inside the filter body.
8.
Install the cleaned cartridge (4) or a new cartridge.
9.
Position the cap (3) with the drain valve (5) facing
downwards and secure it with the couplings (2).
10. Press the button on the filter clogging indicator (1) so that the
red piston returns to its original position.
IMPORTANT
q
If shortly after installing the cleaned cartridge the red pis-
ton of the clogging indicator is visible again, it is necessary
to change the cartridge.
q
Change the filtering element if it has been cleaned for 5
times or used for one year.
WEAM012405
Summary of Contents for PC16R-3
Page 2: ......
Page 24: ...22 THIS PAGE WAS INTENTIONALLY LEFT EMPTY WEAM012405...
Page 25: ...SAFETY AND ACCIDENT PREVENTION 23 WEAM012405...
Page 79: ...THE MACHINE AND ITS OPERATIONS 77 WEAM012405...
Page 190: ...188 THIS PAGE WAS INTENTIONALLY LEFT EMPTY WEAM012405...
Page 191: ...MAINTENANCE 189 WEAM012405...
Page 244: ...242 THIS PAGE WAS INTENTIONALLY LEFT EMPTY WEAM012405...
Page 245: ...TECHNICAL SPECIFICATIONS 243 WEAM012405...
Page 253: ...AUTHORISED OPTIONAL EQUIPMENT 251 WEAM012405...
Page 286: ...284 WEAM012405...
Page 287: ......
Page 288: ...2017 KOMATSU ITALIA MANUFACTURING S p A All Rights Reserved Printed in Europe 02 2017...