Repair
Service and Repair Manual
Cooling system
u
Place guiding rods in place of two screws
3
.
u
Place thermostat housing.
u
Place screws
3
.
u
Remove guiding rods.
u
Place remaining screws.
u
Screw thermostat housing
2
with screws
3, 6
.
u
Tighten screws to torque according to tightening specifications.
Information
Vent coolant circuit at the end of installation.
Specific values
Thermostats LT start to open at 45 °C (113 °F) and are fully opened at 57 °C (135 °F).
Tightening specifications
Refer to standard tightening torques.
(For more information see: 5.3 Standard tightening torques,
3.10.6 Coolant pump HT removal and installation (SL 216)
Previous tasks
q
Drain HT coolant circuit.
q
Remove machinery HT cooling system piping.
Specific safety instructions
NOTICE
Risk of property damage by reuse of sealing.
Leakage by faulty seal.
u
Replace all sealings.
Special tools
Special tool
Designation
Guiding rod M12x100 - Coolant pump (x2)
Tab. 49: Special tools
230
© 2021 by Kohler Co. All rights reserved.
KD83V16 33525088901_2_1 EN_US
2021-07