Repair
Service and Repair Manual
Cooling system
Installation
u
Insert o-ring
7
and flange
6
on pipe from oil cooler casing.
u
Mount pipe
14
with o-rings
3
on flange
6
.
u
Mount coolant pipeline
13
with o-ring
7
on flange
6
.
u
Insert guiding rods in coolant pump
9
.
u
Insert o-rings
10, 11, 12
.
u
Insert coolant pump HT
9
.
u
Tighten screws
1, 16
according to tightening specifications.
u
Remove guiding rods.
u
Tighten remaining screws
16
to torque.
u
Assemble t-pipe
2
, pipe
4
and flange
6
with o-rings
3, 7, 17
.
u
Position assembly with screws
1, 5
and tighten according to tightening specifications.
u
Install test point fitting
8
on coolant pump.
Information
Vent coolant circuit at the end of installation.
Specific values
Not applicable.
Tightening specifications
Refer to standard tightening torques.
(For more information see: 5.3 Standard tightening torques,
3.10.7 Coolant pump LT removal and installation (SL 215)
Previous tasks
q
Drain LT coolant circuit.
q
Remove machinery LT cooling system piping.
q
Remove vibration damper cover.
(For more information see: 3.2.1 Vibration damper cover
removal and installation, page 59.)
q
Remove battery charging alternator cover.
(For more information see: 3.2.2 Battery charging
alternator & PTO cover removal and installation, page 61.)
Specific safety instructions
NOTICE
Risk of property damage by reuse of sealing.
Leakage by faulty seal.
u
Replace all sealings.
232
© 2021 by Kohler Co. All rights reserved.
KD83V16 33525088901_2_1 EN_US
2021-07