Service and Repair Manual
Repair
Exhaust gas system
u
Position V-clamp
9
on exhaust pipe outlets.
u
Lift the turbocharger.
Information
During lifting, make sure the turbocharger does not tilt.
Before installation, the turbocharger should be perfectly aligned with the exhaust pipe connection.
Fig. 195: Aligning turbocharger with exhaust pipe connection
u
Position the turbocharger on the bracket so that the compensator is aligned with the exhaust
pipe connection.
u
Tighten screws
1
with washers
2
to torque.
u
Install V-clamp
9
on exhaust pipe connection to compensator
6
and tighten to torque.
u
Install turbocharger cooling lines.
(For more information see: 3.10.3 Turbocharger cooling lines
removal and installation, page 211.)
Information
Vent coolant circuit at the end of installation.
Specific values
Not applicable.
KD83V16 33525088901_2_1 EN_US
2021-07
© 2021 by Kohler Co. All rights reserved.