9.5
Section 9
Disassembly
9
Figure 9-14. Removing Oil Fill Tube.
Remove Blower Housing and Baffl es
1. See Figure 9-15, 9-16, and 9-17. Remove the
six screws securing the blower housing and any
commonly mounted clamps/brackets. Remove
the blower housing.
Remove Rectifi er-Regulator (If Required)
1. Remove the connector from the rectifi er-regulator.
See Figure 9-13.
2. Remove the two screws securing the rectifi er-
regulator and individual ground lead (if used).
Figure 9-15. Removing Blower Housing and
Baffl es.
Figure 9-17. Removing Blower Housing and
Baffl es.
2. Remove the hex. fl ange valve cover screws
and any loose spacers (stamped steel valve
covers) which also attach the muffl er and/or lift
bracket. Note the assembly orientation for proper
reassembly later.
Oil Fill Tube
Hex. Flange Screw
Muffl er
Bracket
Valve Cover
Valve Cover
Screws
Screws
Hex. Flange
Screws
Cylinder Head
Baffl e
Hex. Flange Screws
Connector
Rectifi er-
Regulator
Ground Lead
Mounting Screws
Cylinder
Baffl e
Cylinder Baffl e
Mounting Screw
Blower
Housing
Figure 9-13. Removing Rectifi er-Regulator (not on
all models).
Remove Extended Oil Fill Tube
1. Remove the hex. fl ange screw securing the oil fi ll
tube to the blower housing/crankcase. See Figure
9-14.
2. Pull the oil fi ll tube out of the crankcase fl ange.
Figure 9-16. Removing Blower Housing and
Baffl es.
Mounting Screws
Summary of Contents for CV11-16
Page 1: ...1 SERVICE MANUAL VERTICAL CRANKSHAFT CV11 16 CV460 465 CV490 495...
Page 2: ......
Page 4: ......
Page 22: ...2 4 Section 2 Special Tools...
Page 30: ...4 4 Section 4 Air Cleaner and Air Intake System...
Page 56: ...6 6 Section 6 Lubrication System...
Page 112: ...9 16 Section 9 Disassembly...
Page 148: ...11 24 Section 11 Reassembly...
Page 149: ......