Chapter 7 Simple fault diagnostics
MDC-2900 Series
0093129012-06
7-10
* In case of alarm caused by an external device, alarm is activated by ALR sentence input from the
external device.
** In case of alarm caused by an external device, ACK sentence is sent out onetime only from the
connector ALR sentence is inputted.
*** Alarm contact closed in case of failure.
While [Alarm] exists, connection between pin 9 and pin 10 of J1 (VDR + external buzzer) becomes
short from open-circuit.
**** Indication priority order can be set for alarms made simultaneously by multiple devices.
Refer to “
PRIORITY
” (page4-7)