Chapter 7 Simple fault diagnostics
MDC-2900 Series
0093129012-06
7-6
7.5 Need to confirm serial input (SERIAL MONITOR)
This procedure is applied to confirm serial input of Display unit.
Serial input of connectors can be confirmed with the following 4 connectors:
GYRO, NAV (J4), EPFS (J5), SDME (J6).
(J7)16P
(J6)6P
(J5)6P
(J4)6P
3P
(J3)12P
8P
(J2)8P
(J1)10P
0.
6.3x32mm
Inter switch
Gyro-unit
Antenna
AIS
SDME
Power
EPFS
NAV
VDR+ ALA RM
Fuse for antenna drive motor
Fuse for modulator high voltage
Fuse for main power
インタースイッチ
アンテナ
船速
電源
位置
航法装置
VDR + 外部ブザー
モータヒューズ
高圧ヒューズ
メインヒューズ
ジャイロユニット
1
Press [MENU] key to display “Menu”.
Select [SYSTEM] => [BITE] => [SERIAL SEL] => then press [Enter] after selection.
2
Select [SERIAL MONITOR] =>.
3
Input data will be displayed.
As the data is input continuously, display continues to move according to data.
By pressing [Enter] key, data display will stop temporarily to confirm data content.
4
Turn track ball to left to complete.
Data confirming item in step 3
In the case that data is not displayed: Confirm input data device connected to Display unit.
In the case that data is displayed but is garbled: Confirm baud rate.
Refer to “
FORMAT
” (page4-46)
In the case that data is displayed correctly: Confirm data format.
Refer to “
Low or doubtful integrity information display
” (page4-46)
Summary of Contents for MDC-2900
Page 1: ......
Page 33: ...Chapter 2 Basic operation Panel MDC 2900 Series 2 2 0093129012 06 2 2 Name of radar display 3 ...
Page 157: ...Chapter 4 General operation Menu MDC 2900 Series 0093129012 06 4 54 MAP ...
Page 158: ...MDC 2900 Series Chapter 4 General operation Menu 0093129012 06 4 55 ERBL LINE RING MAP ...
Page 159: ...Chapter 4 General operation Menu MDC 2900 Series 0093129012 06 4 56 MAP LAT LON LINE ...
Page 160: ...MDC 2900 Series Chapter 4 General operation Menu 0093129012 06 4 57 MAP ...
Page 161: ...Chapter 4 General operation Menu MDC 2900 Series 0093129012 06 4 58 MAP ...
Page 191: ......