Chapter 1 Installation
CVS-872D
1-44
0092607062-01
Connection table of transducer
CVS-872D
J7
Cable
CW-836-3M
Remarks
No.
Signal
Wire color
Signal name.
5
TD2L(Low frequency2)
Black
TD2L
Low frequency
2
TD1L(Low frequency1)
White
TD1L
3
Shield
Shield
Housing GND
Common GND
4
TD2H(High frequency2)
Gree
TD2H
High frequency
1
TD1H(High frequency1)
Red
TD1H
*The ferrite transducer should be connected to the resonance capacitor.
Transducer
Capacitance value
TD-284A
0.1μF
TD-504F
0.047μF
Caution: Please consult a dealer of Koden or Koden about another type of
transducer.