Chapter 3 Maintenance
CVS-872D
3-6
0092607062-01
3.5 If you suspect a trouble
Symptom
Possible cause of trouble
Measure
Even with power on,
nothing is displayed.
•
Fuse is blown.
•
Power voltage is out of
specification (10.8 to 31.2
VDC)
•
Poor connection between
power cable and battery
•
Replace the fuse (See “3.3
Fuse Replacement
”, page
3-2.
•
Use a proper power as per
specification.
•
Check the connection
between power cable and
battery.
After starting up, nothing is
displayed
•
Poor connection between
transducer and Display unit
•
Failure of LCD display panel
•
Check the connection
between transducer and
Display unit.
•
Consult a repair shop or
sales agent.
Much interference noise
•
Improper installation of
transducer
•
Interference from the echo
sounder on other boats.
•
Check the installed position
of transducer (See “1.3
Installation of transducer”,
page 1-6.
•
Implement interference
rejection.
Display of
water temperature / Speed
is abnormal or not
displayed.
•
Poor connection of sensors
connectors
•
Input sources may be
abnormal.
•
Check the connection at
sensor connectors.
•
Check the input sources.
Display of present
location/course is
abnormal or not displayed.
•
Poor connection between
this unit and navigation
equipment
•
Check the connection
between this unit and
navigation equipment.
Summary of Contents for CVS-872D
Page 1: ......
Page 2: ......
Page 16: ...Dimensions CVS 872D xiv 0092607062 01 Dimensions Unit mm inch ...
Page 98: ... This page intentionally left blank ...
Page 104: ... This page intentionally left blank ...
Page 111: ......
Page 112: ......