Chapter 1 Installation
CVS-872D
1-38
0092607062-01
Connection table of transducers
*For low frequency, there are two combinations of cable colors, (yellow and black) and
(blue/white and black/white). Connect the wires to the corresponding pin number.
CVS-872D
Junction box
(JB-34)
Transducer
No.
Connection to:
Pin
No.
Signal name at
connection to:
Color of cable
Remarks
J7
1
Red/TD1H
(high frequency transducer)
1
TD1H
Blue
High frequency
4
Green/TD2H
(high frequency transducer)
2
TD2H
Black
3
Shield
3
GND
Shield
-
-
4
-
-
-
2
White/TD1L
(low frequency transducer)
5
TD1L
Yellow
(Blue/ white)*
Low frequency
5
Black/TD2L
(low frequency transducer)
6
TD2L
Black
(Black/White)*
3
-
7
GND
Shield
-
8
-
-
-
-
-
-
9
-
-
-
J6
4
Shield
10
Shield
Shield (In)
Shield
8
Black / XID GND
11
XID GND
Shield (Out)
XID
3
Orange / XID data
12
XID Data
Orange
7
Red/
Water temp. sensor input
13
Water temp.
sensor (+)
Brown
Water temp.
sensor
6
Green/
Water temp. sensor power
14
Water temp.
sensor (power)
White
1
-
15
-
-
2
-
16
-
-
Summary of Contents for CVS-872D
Page 1: ......
Page 2: ......
Page 16: ...Dimensions CVS 872D xiv 0092607062 01 Dimensions Unit mm inch ...
Page 98: ... This page intentionally left blank ...
Page 104: ... This page intentionally left blank ...
Page 111: ......
Page 112: ......