Sequence Example (Normal Sequence)
This section explains how to use the operation panel to enter the following example
sequence.
This section provides an example of how to execute a sequence with two programs on the
PLZ164WH.
• Program 1
Memo: PROGRAM1, Mode: CC, Loop: 1, Chain: Program 2
• Program 2
Memo: PROGRAM2, Mode: CC, Loop: 2
State that the load will be in after the sequence ends: Off, Current at the end of the
sequence: 0 A, Chain: Off
Program 2 starts after the three steps in program 1 have been executed. When the three
steps in program 2 have been executed, the first execution of program 2 is finished. The
sequence is complete when the second execution of program 2 is finished.
Step
Setting
Step Execution Time
LOAD
RAMP
TRIG
Step 1
6 A
200 s (3 min 20 s)
On
On
Off
Step 2
6 A
150 s (2 min 30 s)
On
Off
Off
Step 3
0.3 A
80 s (1 min 20 s)
Off
Off
On
Step
Setting
Step Execution Time
LOAD
RAMP
TRIG
Step 1
8.1 A
200 s (3 min 20 s)
On
On
Off
Step 2
3 A
50 s
On
Off
Off
Step 3
7.2 A
150 s (2 min 30 s)
On
On
Off
8.1 A
6 A
7.2 A
3 A
Execution (RUN)
6 A
200 s
LOAD ON
RAMP ON
6 A
150 s
LOAD ON
RAMP OFF
8.1 A
200 s
LOAD ON
RAMP ON
7.2 A
150 s
LOAD ON
RAMP ON
8.1 A
200 s
LOAD ON
RAMP ON
Step 1
Program 1
Program 2
Program 2
Step 1
Step 2
Step 2
Step 3
Step 3
Step 1
Step 3
Step 2
CC
Setting
0.3 A
80 s
LOAD
OFF
RAMP
OFF
3 A
50 s
LOAD
ON
RAMP
OFF
3 A
50 s
LOAD
ON
RAMP
OFF
7.2 A
150 s
LOAD ON
RAMP ON
TRIG
TRIG OFF
TRIG OFF
TRIG
ON
TRIG OFF
TRIG OFF
TRIG
OFF
TRIG OFF
TRIG OFF
TRIG
OFF
Input current