72
PLZ-4WH
Sequence Example (Normal Sequence)
Editing program 2
After you finish editing program 1, edit program 2.
Memo
You can move the cursor
by
pressing , , ,
and .
To exit the sequence
editing screens, press
PREV (SHIFT+
).
1
Press PREV (SHIFT+ ) three times to display the
program editing screen.
2
Set the program number to 2.
If the cursor is not blinking at No., press
and
to move it
there. Turn the rotary knob to select 2.
3
Press
to move the cursor to Memo, and enter
“Program2.”
Enter the text using the rotary knob and and
.
4
Press
to move the cursor to Mode, and select an
operation mode (NCC mode).
5
Press
to move the cursor to Range, and set the
current and voltage ranges to 8.25 A and 650 V.
6
Press
to move the cursor to Loop, and set the
number of times to execute the program to 2.
7
Press
to move the cursor to Last Load, and
select the state that the load will be in after the
sequence ends (select OFF).
8
Press
to move the cursor to Last Set, and select
the current that the load will supply after the
sequence ends (select 0 A).
9
Press
to move the cursor to Chain, and set it to
OFF.
To end the sequence after program 2 is executed twice,
select OFF.
10
Press NEXT (SHIFT+ ) or ENTER.
The step value screen appears.
SEQ
PREV
NEXT
No. :
1
Memo :
Mode :
NCC
Loop :
0001
Ran
g
e : 8.25A, 650V
Program1
SEQ
PREV
NEXT
No. :
2
Memo : Pro
g
ram2
Mode : NCC
Loop : 0002
Ran
g
e : 8.25A, 650V
SEQ
PREV
NEXT
Last Load
: OFF
Last Set
: 0.0000
A
Chain :