8-2 Specifications
OT01-PCR-LA/2
8.1
Speci
fi
cations
8.1.1
Output Expansion Kits (Single-phase/Single-phase,
Three-wire Switching)
8.1.2
Parallel Operation
Output terminal section
Model name OT01-PCR4000LA/2
OT01-PCR8000LA/2
OT01-PCR12000LA/2
Maximum output current
Single-phase output
40 A
80 A
120 A
Single-phase,
three-wire output
20 A
40 A
60 A
Output terminal board connec-
tion screws
Single-phase output
M6
M6
M8
Single-phase,
three-wire output
M6
Insulation resistance: Input to chassis, output to chas-
sis
500 V DC, 3 M
Ω
or more
Withstand voltage: Input to chassis, output to chassis
1500 V AC for one minute
External dimensions (chassis)
430 mm x 84 mm x
400 mm
430 mm x 218 mm x
400 mm
430 mm x 218 mm x
400 mm
Weight
Approx. 6.5 kg
Approx. 16 kg
Approx. 17 kg
Operating ambient temperature/humidity
0 °C to +40 °C/20 % to 80 % RH (no condensation allowed)
Driver cards and cables
Single-phase, Three-wire Output Driver
A set of 2P03-OT01-PCR-LA
(specially designed for the OT01 series)
Parallel Operation Driver (for the master unit)
A set of PD03M-OT01-PCR-LA
(specially designed for the OT01 series)
Parallel Operation Driver (for the slave units)
A set of PD03S-OT01-PCR-LA
(specially designed for the OT01 series)
Power connection cables
5.5 mm
2
/2.5 m,
6 cables
8 mm
2
/2.5 m,
6 cables
14 mm
2
/2.5 m,
6 cables
Signal connection cables
With a connector at both ends, 6 cables
Operation Manual
One copy
Output voltage stability, waveform distortion ratio, response rate
Output current variation
(with respect to 0 % to 100 % changes in rating)
Within ± 1 V (*1) (*2)
Output
frequency
variation
AC mode (with respect to changes in the
rated range)
Within ± 1.2% (*1) (*3)
Output voltage waveform distortion ratio (*10)
0.5 % or less (*1) (*2)
Output voltage response rate (*11)
60
μ
s (typical value) (*4)
Ammeter and wattmeter
Total values for parallel operation (*5)
Summary of Contents for OT01-PCR12000LA/2
Page 10: ...VIII Contents OT01 PCR LA 2 ...
Page 16: ...1 6 General OT01 PCR LA 2 ...
Page 44: ...2 28 Installation and Preparation for Use OT01 PCR LA 2 ...
Page 56: ...4 8 Part Names and Functions OT01 PCR LA 2 ...
Page 64: ...5 8 Single phase Parallel Operation OT01 PCR LA 2 ...
Page 82: ...6 18 Single phase Three wire Operation OT01 PCR LA 2 ...
Page 94: ...1 2 Index OT01 PCR LA 2 ...
Page 95: ......
Page 96: ...OUTPUT EXPANSION KIT OT01 PCR LA 2 OPERATION MANUAL ...