OT01-PCR-LA/2
Single-phase, Three-wire Operation 6-11
For the line voltage display mode:
6.10.3 Switching to the Current or Power Display Mode
Each time the SHIFT key is pressed followed by the F3 key in the Home Position,
the current and power display mode changes as follows:
6.10.4 Sequence Operation
In the sequence setting mode, items available in the DC or AC + DC mode cannot
be set. In addition, AC voltage (Vac) applies phase voltage setting.
6.10.5 Harmonic Current Analysis Function
The Remote Controller (RC04-PCR-LA) connected to the U-phase power supply
allows harmonics in a load current to be analyzed in each of the U and V phases.
For this operation, add the following step between steps 2 and 3 in “4.4.3 Harmonic
Current Analysis Function” in the RC04-PCR-LA Operation Manual.
2a. Select the phase that performs harmonic current analysis.
• Pressing the F1 key selects phase U and pressing the F3 key selects phase V.
Thereafter, follow the procedure from step 3 onward as speci
fi
ed in “4.4.3 Har-
monic Current Analysis Function” in the RC04-PCR-LA Operation Manual.
• The letter “U” or “V,” indicating the selected phase, appears at the left of the
fi
rst
component of the harmonic current analysis result indicated on the display.
C u r
r e n t
H a r m o n i c
U
V
F1
F2
F3
F4
F5
U-to-V phase voltage
Power, VA, and power factor (no measured value is displayed)
RMS
Ip
Iph
UWATT (U-phase power)
WATT (total power of the two phases)
Summary of Contents for OT01-PCR12000LA/2
Page 10: ...VIII Contents OT01 PCR LA 2 ...
Page 16: ...1 6 General OT01 PCR LA 2 ...
Page 44: ...2 28 Installation and Preparation for Use OT01 PCR LA 2 ...
Page 56: ...4 8 Part Names and Functions OT01 PCR LA 2 ...
Page 64: ...5 8 Single phase Parallel Operation OT01 PCR LA 2 ...
Page 82: ...6 18 Single phase Three wire Operation OT01 PCR LA 2 ...
Page 94: ...1 2 Index OT01 PCR LA 2 ...
Page 95: ......
Page 96: ...OUTPUT EXPANSION KIT OT01 PCR LA 2 OPERATION MANUAL ...