4-4 Part Names and Functions
OT01-PCR-LA/2
[10] TO J4-2 SLAVE connector
Using a supplied signal connection cable, make a connection between this con-
nector and the slave PCR-LA power supply’s J4 connector.
[11] TO SENSING connector
This connector sends out a line voltage signal. Using the supplied signal connec-
tion cables, make connections between this connector and the PCR-LA power
supplies’ SENSING terminal boards.
[12] EXT CONT terminal
This is for external contact inputs for the SYSTEM POWER switch and WIRING
switch.
[13] TO PD03M-OT01-PCR-LA connector
This connector outputs a 1P/1P3W switching signal. Using the supplied signal
connection cable, connect this connector to PD03M-OT01-PCR-LA in the master
PCR-LA power supply.
[14]
Grounding terminal