Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
25
WorkZone
®
Desks - “810” 10-Wire Electrical System
Assembly Instructions
20
assemble units as described herein only . To do otherwise
may result in instability . all screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly . Failure to assemble properly, or to secure parts may
result in assembly failure and personal injury .
DataLink
®
Training Table System - "810" 10-Wire Electrical System
Assembly Instructions
810-Universal Wire connection
Diagrams
have a certified electrician hard-wire the
panel power infeed to the building power
source according to the national electrical
code and any other applicable local codes .
See the chart for proper wiring connection
to available power .
6-2-2
receptacles
available
Wires to be used
gauge
of wire
circuit 1
black
White/black Letters
green or bare
12
10
12
circuit 2
red
White/black Letters
green or bare
12
10
12
circuit 3
blue
White/black Letters
green or bare
12
10
12
circuit 4i
Pink
White/Purple Letters
green/yellow Stripe
or gray
12
10
12
circuit 5i
Tan
White/red Letters
green/yellow Stripe
or gray
12
10
12
circuit 6i
orange
White/red Letters
green/yellow Stripe
or gray
12
10
12
120/208V W YE (THREE PHASE)
120/240V SINGLE PHASE
GREEN/YELLOW OR GRAY (ISOLATED GROUND 4)
RED (LINE 2)
DO NOT CONNECT ORANGE (LINE 6)
DO NOT CONNECT TAN (LINE 5)
BLUE (LINE 3)
GREEN OR BARE (GROUND 1,2 & 3)
W HITE/BLACK (NEUTRAL 1,2 & 3)
PINK (LINE 4)
W HITE/RED (NEUTRAL 4)
BLACK (LINE 1)
CIR. 1
DEAD M ETAL
CIR. 2
CIR. 3
CIR. 4
CIR. 5
CIR. 6
GREEN/YELLOW OR GRAY (ISOLATED GROUND 4)
W HITE/BLACK (NEUTRAL 1,2)
W HITE/RED (NEUTRAL 4)
GREEN OR BARE (GROUND 1,2)
DO NOT CONNECT TAN (LINE 5)
BLUE (LINE 3)
DO NOT CONNECT ORANGE (LINE 6)
DO NOT CONNECT RED (LINE 2)
BLACK (LINE 1)
PINK (LINE 4)
CIR. 4
CIR. 5
CIR. 6
DEAD M ETAL
CIR. 2
CIR. 1
CIR. 3
120/208V W YE (THREE PHASE)
120/240V SINGLE PHASE
GREEN/YELLOW OR GRAY (ISOLATED GROUND 4,5 & 6)
RED (LINE 2)
ORANGE (LINE 6)
TAN (LINE 5)
BLUE (LINE 3)
GREEN OR BARE (GROUND 1,2 & 3)
W HITE/BLACK (NEUTRAL 1,2 & 3)
PINK (LINE 4)
W HITE/RED (NEUTRAL 4,5 & 6)
BLACK (LINE 1)
CIR. 1
DEAD M ETAL
CIR. 2
CIR. 3
CIR. 4
CIR. 5
CIR. 6
GREEN/YELLOW OR GRAY (ISOLATED GROUND 4,5)
W HITE/BLACK (NEUTRAL 1,2)
W HITE/RED (NEUTRAL 4,5)
GREEN OR BARE (GROUND 1,2)
TAN (LINE 5)
DO NOT CONNECT BLUE (LINE 3)
DO NOT CONNECT ORANGE (LINE 6)
RED (LINE 2)
BLACK (LINE 1)
PINK (LINE 4)
CIR. 4
CIR. 5
CIR. 6
DEAD M ETAL
CIR. 2
CIR. 1
CIR. 3
6-2-2 connection Diagrams
6-2-2 connection Diagrams to an 8-Wire building
20
assemble units as described herein only . To do otherwise
may result in instability . all screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly . Failure to assemble properly, or to secure parts may
result in assembly failure and personal injury .
DataLink
®
Training Table System - "810" 10-Wire Electrical System
Assembly Instructions
810-Universal Wire connection
Diagrams
have a certified electrician hard-wire the
panel power infeed to the building power
source according to the national electrical
code and any other applicable local codes .
See the chart for proper wiring connection
to available power .
6-2-2
receptacles
available
Wires to be used
gauge
of wire
circuit 1
black
White/black Letters
green or bare
12
10
12
circuit 2
red
White/black Letters
green or bare
12
10
12
circuit 3
blue
White/black Letters
green or bare
12
10
12
circuit 4i
Pink
White/Purple Letters
green/yellow Stripe
or gray
12
10
12
circuit 5i
Tan
White/red Letters
green/yellow Stripe
or gray
12
10
12
circuit 6i
orange
White/red Letters
green/yellow Stripe
or gray
12
10
12
120/208V W YE (THREE PHASE)
120/240V SINGLE PHASE
GREEN/YELLOW OR GRAY (ISOLATED GROUND 4)
RED (LINE 2)
DO NOT CONNECT ORANGE (LINE 6)
DO NOT CONNECT TAN (LINE 5)
BLUE (LINE 3)
GREEN OR BARE (GROUND 1,2 & 3)
W HITE/BLACK (NEUTRAL 1,2 & 3)
PINK (LINE 4)
W HITE/RED (NEUTRAL 4)
BLACK (LINE 1)
CIR. 1
DEAD M ETAL
CIR. 2
CIR. 3
CIR. 4
CIR. 5
CIR. 6
GREEN/YELLOW OR GRAY (ISOLATED GROUND 4)
W HITE/BLACK (NEUTRAL 1,2)
W HITE/RED (NEUTRAL 4)
GREEN OR BARE (GROUND 1,2)
DO NOT CONNECT TAN (LINE 5)
BLUE (LINE 3)
DO NOT CONNECT ORANGE (LINE 6)
DO NOT CONNECT RED (LINE 2)
BLACK (LINE 1)
PINK (LINE 4)
CIR. 4
CIR. 5
CIR. 6
DEAD M ETAL
CIR. 2
CIR. 1
CIR. 3
120/208V W YE (THREE PHASE)
120/240V SINGLE PHASE
GREEN/YELLOW OR GRAY (ISOLATED GROUND 4,5 & 6)
RED (LINE 2)
ORANGE (LINE 6)
TAN (LINE 5)
BLUE (LINE 3)
GREEN OR BARE (GROUND 1,2 & 3)
W HITE/BLACK (NEUTRAL 1,2 & 3)
PINK (LINE 4)
W HITE/RED (NEUTRAL 4,5 & 6)
BLACK (LINE 1)
CIR. 1
DEAD M ETAL
CIR. 2
CIR. 3
CIR. 4
CIR. 5
CIR. 6
GREEN/YELLOW OR GRAY (ISOLATED GROUND 4,5)
W HITE/BLACK (NEUTRAL 1,2)
W HITE/RED (NEUTRAL 4,5)
GREEN OR BARE (GROUND 1,2)
TAN (LINE 5)
DO NOT CONNECT BLUE (LINE 3)
DO NOT CONNECT ORANGE (LINE 6)
RED (LINE 2)
BLACK (LINE 1)
PINK (LINE 4)
CIR. 4
CIR. 5
CIR. 6
DEAD M ETAL
CIR. 2
CIR. 1
CIR. 3
6-2-2 connection Diagrams