16
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
14. For 10-wire power infeed,
position the flexible conduit
between the vertical leg
members and plug the power
infeed connection into the
10-wire harness under the table.
Route the uncased 10-wire
through 90° metal connector
and through the access hole of
the infeed outer wireway. Lay the
oval conduit flat (not on edge)
into the bottom half of the round
90° metal connector. Assure the
maximum amount of conduit is
inside the fitting and connect
the top half of the fitting to the
bottom. Use screws supplied
and assure that the two sections
are properly connected, securely
capturing the flexible oval
conduit (Figure 5).
Note:
The conduit and
connector assembly has been
UL Listed in KI’s UL file to meet
the requirements of UL 1286
“Office Furnishings”. The 90°
metal connector is limited to the
following models: EGS Appleton
AC96 or Cooper Crouse 738.
Substitutions are not allowed.
15. Route the uncased 10-wire
through the 90° pulling elbow.
Next screw or thread the 90°
metal connector into the 90°
pulling elbow, sandwiching the
steel infeed panel. Slide the
liquid-tight connector onto the
10-wires and connect it to the
90° pulling elbow (Figure 5)
16. Set the infeed outer wireway
up against the outside of the
vertical leg members with
support lip resting on the foot of
the leg. Position the infeed inner
wire way up against the inside
of the vertical leg members.
Fasten infeed inner wireway to
infeed outer wireway with six
#10-32 x 1½” screws
(Figure 5).
17. Determine the appropriate
length for the liquid-tight
conduit (to power source) and
cut it to size. Slide the
liquid-tight conduit onto the
10-wires and connect the
conduit to the connector on
the elbow. Finally the liquid-
tight conduit may be fastened
to a junction box (customer
supplied) and the 10-wires can
be cut to size and connected to
the power source (Figure 5).
Important:
The Listed
conduit of the power infeed is
intended to be terminated with
a commonly available Listed
conduit fitting appropriate for
the type and trade size of the
conduit.
Note:
The power infeeds
are to be connected to the
power source by a qualified
electrician who must also
check the electrical integrity
of the finished system. These
steps are intended as a
guideline for the installation.
18. The power/data door that
is attached to the modesty
panel snaps onto the two
pre-installed door clips at the
underside of the worksurface.
The S-shaped power/data
divider that was installed into
the power/data door is in
place to separate power from
data lines (optional).
Note:
This channel is not to be
used for routing extension
cords. Power supply
cords are not to be routed
across or through more
than one complete unit/
worksurface.
Data lines can
be run through worksurface
grommets and exit through
knockout in infeed outer
wireway or notch on inside of
center vertical wireway. Snap
the power/data door to the
door clips when power and
data lines have been run.
WorkZone
®
Desks - 24”, 30” x 60”, 66” & 72” Tops with Power & Data
Assembly Instructions
10-wire
harness
power infeed
infeed
inner
wireway
infeed
outer
wireway
uncased
10-wire
liquid-tight
connector
liquidtight conduit
(to power source)
90 pulling elbow
o
round
90 metal
connector
o
support lip
Figure5
oval
flexible
conduit
Figure 5