8-4 Programming Mode
8.5
Multi Line Messages
The multiline message is effective when ATT signal is "Low". The following functions are
supported in this unit.
8.6
Status Register
The status resistor can read the status of this unit (alarm and error) by the serial pole,
Each bit represents as follows:
Function
Code
Description
Memo
Device clear
20
DCL (Device Clear)
4
SDC (Selected Device Clear)
Trigger
8
GET (Group Execute Trigger)
repeat the lastly issued command
Panel Operations
1
GTL (Go To Local)
release remote condition
17
LLO (Local Lock Out)
prevent from releasing remote condition
Notes:
The code of the multiline command is sent as binary data
So it is impossible to access by the sending command usually used.
becomes the same condition as power
ON
Bit(HEX)
abbrev
Description
Note
80
ALM
Alarm Issue
When Bits of ST0-ST2 is up , then it
setup.
40
SRQ
Service Request
When Interupt request is issued.
20
ERR
Command Error
Send back the status of executing
15
BS
Booster Error
Send back the status of the booster
10
BUSY
command in execution
Send back the status of executing
08
LIMIT
Status of Curr. limit
04
ST2
Alarm Status is send by the following No
02
ST1
0:Normal , 1: Over Volt., 2; Overheat
01
ST0
3: Reverse Connection, 4: Over Power
It is set when something is wrong with
the Load Control
Summary of Contents for ELS-304
Page 1: ...ELS 304 High SPEED Electronic Load OPERATION MANUAL Engineering Company SERIES ...
Page 12: ...ELS 304 ...
Page 22: ...ELS 304 2 8 Connections ...
Page 50: ...ELS 304 6 4 Operations for Meas Modes ...
Page 72: ...ELS 304 8 18 Programming Mode ...
Page 76: ...ELS 304 9 4 Specifications ...
Page 80: ......