![KG ELS-304 Operation Manual Download Page 21](http://html.mh-extra.com/html/kg/els-304/els-304_operation-manual_1962713021.webp)
ELS-304
Connections
2-7
2.4
TRIG OUT
TRIG OUT signal can be used when you observe a waveform in dynamic mode operation.
・
TRIG
OUT of this product is an isolated output.
・
Trigger signal is outputted only when dynamic mode operation.
・
Trigger output: pulse transformer type, max output peak volt. +/- 3V (typ), pulse
width 4usec (typ) , output impedance : 50ohm (typ)
Fig.2-4-1
TRIG OUT and Current. Waveform
NOTE
TIME (msec)
GND
+3V(typ)
Current Waveform
TRIG OUT Waveform
DYNAMIC RUN
ON
DYNAMIC RUN
OFF
4us(typ)
SET(CC1)
SETCC2)
TIME(CC1)
TIME(CC2)
RESP(CC1)
(A/usec)
RESP(CC2)
(A/usec)
Timing when trigger signal is outputted
from the TRIG OUT terminal
-3V(typ)
+2V