ELS-304
Programming Mode
8-3
8.3
Load Setting Commands
8.4
System Commands
Function
Code
Description
Memo
readbak the version V
readback the ROM's version
Release Alarm
AC
release alarm
Inrialization
INI
Initialize
Remo condition remains
Clear
CL
Clear
becomes the same as power ON
Response Data
T0
Comma, Space
T1
Comma
T2
Space
SRQ Settings
S0
None
S1
Command Error occurs
S2
Alarm Occurrs
S3
Command Error and Alarm occurs
Setup the condition to trigger the SRQ
Bound symbol of response data
Function
Command
Description
Memo
Load Setting
CC{NR2}
Constant Curr.〔A〕
CR{NR2}
Constant Resistor〔Ω〕
CV{NR2}
Constant Volt.〔V〕
CP{NR2}
Constant Power 〔W〕
Short
Curr. range is set as HIGH range
Dynamic
DP{NR1}
range: 0〜1
Section where DC DT and DR
1:define section "CC-1"
commands are effective is defined
2:define section "CC-2"
DC{NR2}
curr. value(A) in section.
Effective for the section defined by
DT{NR2}
time period (msec) of section.
DP command
DR{NR2}
set load resp. (slew rate) (A/μsec)
Curr. Setting Range
RC{NR1}
range : 0〜2
*1 Load current range
0: auto range
1:High range
2:Low raneg
Volt. Setting Range
RV{NR1}
range: 1〜2
*1 Load volt. range
1:High range
This setting infludences CR and CV
2:Low raneg
settings.
Output Control
SW{NR1}
range: 0〜1
0:load OFF
1:load ON
Load Response Setting GC{NR2}
resp. time [μ/A] in CC setting
Valid for CC and CV setting only.
GV{NR2}
resp. time [%] in CV setting
or max default value in other modes.
Curr. Limit Setting
LS{NR2}
Curr value[A] up to max. rated value. No limit for load curr. setting range.
Notes:
{ } : you can NOT mot in this pa NR1・・・・・・ integral value
NR2・・・・・・ real value
*1: Setting range and the meas. range of load section can not be setup independently
but should be set as identical..
Load OFF becomes no load condition
inactivating load settings.
CX{NR2}
Curr.value when ext.cont.volt is 10V
〔A〕
CS
Both mode and setting value can be
setup.
range: 0〜1
0:stop/shift dynamic operation
1: start dynamic operation
This command is to select the
Dynamic operation mode only.
Detailed Setting shall be done by
other commands below
CD{NR1}
Summary of Contents for ELS-304
Page 1: ...ELS 304 High SPEED Electronic Load OPERATION MANUAL Engineering Company SERIES ...
Page 12: ...ELS 304 ...
Page 22: ...ELS 304 2 8 Connections ...
Page 50: ...ELS 304 6 4 Operations for Meas Modes ...
Page 72: ...ELS 304 8 18 Programming Mode ...
Page 76: ...ELS 304 9 4 Specifications ...
Page 80: ......