![KG ELS-304 Operation Manual Download Page 33](http://html.mh-extra.com/html/kg/els-304/els-304_operation-manual_1962713033.webp)
ELS-304
Operations of Load Modes
5-3
(1) Ten keys
You can input values directly by using the “ten keys”.
The values you can input are those in the load mode currently displayed.
You can inputting/changing values regardless of Load ON/OFF.
Use “ten keys” to input values and press “ENT” key to confirm it.
Example: setup 98.50A in CC mode
Note:
you need to select CC mode before you input the value.
Use “ten keys” to input
8
9
.
5
. Then you can find underscored “98.5” is
displayed as shown below. While underscored, the values are under setting up.
In this case, you didn’t change load mode, (CC mode is still selected.)
Please not that Load won’t be activated unless you operate the following step.
The load won’t start operation according to above setting until you press “ENT” key.
(2) Rotary knob
If you turn the “rotary knob” in a clockwise/counterclockwise direction, setting values
increases / decreases respectively.
You can changing values regardless of Load ON/OFF.
・
If you turn the knob too fast, setting value may not always matches the steps you turned the
knob.
(2) Increase/decrease value per step of the knob
The minimum resolution when you turn the knob is one step. You can change the resolution
of this one step. The resolution of one step is displayed in icons as shown below.
0.001
0.01
0.1
1.0
10.0
These resolution values are common to all load modes.
To change the resolution, press “CE” key. When you press the “CE” key, resolution increases.
But after 10.0, it goes to 0.001 again.
Supplement
Decreasease
Increasease
Summary of Contents for ELS-304
Page 1: ...ELS 304 High SPEED Electronic Load OPERATION MANUAL Engineering Company SERIES ...
Page 12: ...ELS 304 ...
Page 22: ...ELS 304 2 8 Connections ...
Page 50: ...ELS 304 6 4 Operations for Meas Modes ...
Page 72: ...ELS 304 8 18 Programming Mode ...
Page 76: ...ELS 304 9 4 Specifications ...
Page 80: ......