Switcher events and device control events can be programmed to occur together, in which case
the Controller area would be programmed as appropriate for the device control event desired.
For any event, the Port Number in the Comm Port area must be correctly specified (typically 2).
This is usually set once and left alone for all future operations since it will not change.
The three supported Leightronix controllers each have different Switcher or Router areas that
reflect their individual input/output capabilities. Switcher or router capabilities are defined by
how many inputs come into a unit and how many outputs go out.
That means for multiple inputs and outputs, decisions must be made as to which input to select
and from which output or outputs the unit sends its signal. The Switcher or Router area is used
make these specifications, so it’s Input and Output drop down menus offer the appropriate
choices for each unit.
The MINI-T is an 8 X 1 (8 inputs, 1 output). Since it has only one output, when it is the selected
device, this area is designated as Switcher. The Input drop down menu offers input selections
from 1 – 8 to choose from and there is no output drop down menu. An input selection of “—“
indicates no switch.
The PRO-8 is an 8 X 3 (8 inputs, 3 outputs). Since it has three outputs to choose from, when it is
the selected device, this area is designated as Router and an Output drop down menu appears on
the window. The Input drop down menu offers input selections from 1 – 8 and the Output drop
down menu offers output selections from 1 – 3 to choose from. Multiple outputs can be chosen
for any event. An input selection of “—“ indicates no switch.
The PRO-16 is a 16 X 4 (16 inputs, 4 outputs). Since it has three outputs to choose from, when it
is the selected device, this area is designated as Router and an Output drop down menu appears
on the window. The Input drop down menu offers input selections from 1 – 16 and the Output
drop down menu offers output selections from 1 – 4 to choose from. Multiple outputs can be
chosen for any event. An input selection of “—“ indicates no switch.
The Delay drop down menu for all controller types allows a delay in seconds from 0 – 99 to be
specified for each switcher event.
ADD AVR8 EVENT
To access the INSTANT COMMAND menus and functions click
COMMUNICATIONS and select INSTANT EVENTS/CONTROLS