163
Chapter 4 Remote Interface Reference
Using the APPLy Command
4
Output Frequency
• For the frequency parameter of the
APPLy
command, the output
frequency range depends on the function specified. You can substitute
“MINimum”, “MAXimum”, or “DEFault” in place of a specific value
for the frequency parameter. MIN selects the lowest frequency
allowed for the function specified and MAX selects the highest
frequency allowed. The default frequency is 1 kHz for all functions.
• Limits Due to Function: The frequency limits are determined by the
function specified in the
APPLy
command. The
APPLy
command
always sets both the function and the frequency, and the specified
frequency must be appropriate for the function. For example, the
command
APPL:RAMP 10 MHz
results in a “Data out of range” error.
The frequency is set to 100 kHz, which is the maximum for a ramp
waveform.
Function
Minimum Frequency
Maximum Frequency
Sine
Square
Ramp
Pulse
Noise, DC
Arbs
1 mHz
1 mHz
1 mHz
1 mHz
Not Applicable
1 mHz
10 MHz
10 MHz
100 kHz
5 MHz
Not Applicable
3 MHz
33210A users guide.book Page 163 Wednesday, July 16, 2008 11:16 AM
Summary of Contents for 33210A
Page 1: ...Keysight 33210A 10 MHz Function Arbitrary Waveform Generator User s Guide ...
Page 2: ......
Page 3: ......
Page 14: ...12 Contents Contents 33210A users guide book Page 12 Wednesday July 16 2008 11 16 AM ...
Page 15: ...1 1 Quick Start 33210A users guide book Page 13 Wednesday July 16 2008 11 16 AM ...
Page 53: ...3 3 Features and Functions 33210A users guide book Page 51 Wednesday July 16 2008 11 16 AM ...
Page 273: ...5 5 Error Messages 33210A users guide book Page 271 Wednesday July 16 2008 11 16 AM ...
Page 301: ...6 6 Application Programs 33210A users guide book Page 299 Wednesday July 16 2008 11 16 AM ...
Page 311: ...7 7 Tutorial 33210A users guide book Page 309 Wednesday July 16 2008 11 16 AM ...
Page 335: ...8 8 Specifications 33210A users guide book Page 333 Wednesday July 16 2008 11 16 AM ...