109
Chapter 3 Features and Functions
Triggering
3
Software (Bus) Triggering
The bus trigger mode is available only
from the remote interface. This mode is similar to the manual trigger
mode from the front panel, but you trigger the function generator by
sending a bus trigger command. The function generator initiates one
sweep or outputs one burst each time a bus trigger command is received.
• To select the bus trigger source, send the following command.
TRIGger:SOURce BUS
• To trigger the function generator from the remote interface (GPIB,
USB, or LAN) when the Bus source selected, send the
TRIG
or
*TRG
(trigger) command. The front-panel
key is illuminated when the
function generator is waiting for a bus trigger.