Code
Problem
Resolution
132
Control box supports voltage
control only and fusion specified
is not voltage control.
Not all control boxes support current or energy control. Attach
a fitting that requires voltage control or contact an authorized
representative
(See page 19)
to see if an update is available for
your processor.
138
The fitting was disconnected
before the specified countdown
time elapsed.
Do not disconnect the fitting before the manufacturer
’
s
recommended countdown time has expired.
140
The fusion was shutoff to
protect the processor from
damage due to extremely high
fusion current.
This is typically caused when a direct short is made across the
Output Lead Ends. If there are no obvious problems with the
fitting or the output cable, then the processor will need to be
returned for service.
141
The ambient temperature is too
low to fuse fittings of this type.
Same as error 101.
142
The processor believes that the
same fitting was fused twice.
Do not fuse a fitting more than two (2) times unless directed so
by the fitting manufacturer.
143
The fitting was disconnected
before the specified heat soak
time was observed.
Do not disconnect the fitting before the manufacturer
’
s
recommended heat soak time has expired.
144
The output is cycling and cannot
be controlled to the requested
level.
This is more than likely caused by a fluctuating power supply.
Eliminate all extension cords and ensure that the processor is
the only device operating on the circuit.
145
There is an error communicating
with the USB Flash Drive.
Be sure the drive is formatted as FAT or FAT32 with a cluster
size of 512 bytes.
149
No zero crossing detected
during fusion.
A problem has been detected with the output circuit in the
processor. The unit must be returned to the manufacturer for
service.