To PERFORM SECONDARY CHECK:
1.
Press the
START button
to begin a Calculated Resistance check and attempt to continue the fusion.
The processor will begin the fusion process and display a screen similar following:
FUSION NUMBER: 0125
60 sec
FAILURE TO VERIFY THAT THE FUSION INFORMATION IS CORRECT BEFORE STARTING A FUSION
COULD RESULT IN SIGNIFICANT DAMAGE TO PROPERTY, PERSONAL INJURY, AND/OR DEATH.
2.
If the Calculated Resistance check is successful, the fusion will proceed normally. When the fusion
is complete, a screen similar to the following will be displayed:
COOLING TIME: 5 min
Actual Fusion Time
60 sec
PRESS START
Press the
START button
to continue.
3.
If the Calculated Resistance check fails, the processor will display a screen similar to the following:
ERROR 102 RECEIVED
Resistance 16.578
Min:1.21 Max:1.78
Hold START to clear
Press and hold the
START button
to clear the error code. Follow the prompts on the processor display. See
page 54 for information how to troubleshoot an Error Code 102.