Kerotest Manufacturing
–
SHANNON & PAF III OPERATORS MANUAL - REV 3
Page 25 of 60
Remove the scanning device (
i.e. barcode wand or SMART Scanner™) from the protective sheath. Scan the
barcode from the fitting about to be fused. See page 36 for scanning techniques and suggestions.
Whenever possible, use the barcode label attached to the fitting about to be fused. If this is not possible, use
a barcode from an
identical
fitting made by the same manufacturer to ensure that the fusion parameters are
correct.
UNDER NO CIRCUMSTANCES SHOULD A BARCODE FROM A SIMILAR FITTING BE USED.
NOTE:
If the scanning device is inoperative, see page 26 for details about how a fusion can be completed without
using a scanning device.
Once the barcode has been successfully scanned, the
Kerotest Electrofusion Processor
will display a screen
similar to the following:
NOTE:
If Pipe/Fitting Traceability is set to ON or OPT, the operator will be prompted to scan traceability data at
this time. Refer to the appropriate section on page 41 for instructions that detail how to gather this data
.
VERIFY SETUP
INNO 2
” COUPL
40.0V 60 sec
PRESS START
The VERIFY SETUP screen shows the following information:
•
The fitting type (Innogaz 2
” Coupler).
•
The requested output (40.0 Volts).
•
The total temperature-compensated fusion time in seconds (In this case, 60 seconds).
The VERIFY SETUP screen allows the operator a final opportunity to verify that the fusion parameters
displayed are correct and match the parameters specified by the fitting manufacturer before starting the
fusion.
ALWAYS pay close attention and verify the information on this screen is correct before pressing
START.
IT IS THE RESPONSIBILITY OF THE OPERATOR TO VERIFY THAT ALL THE INFORMATION DISPLAYED IS
CORRECT PER THE FITTING MANUFACTURER’S RECOMMENDATI
ONS FOR FUSING THE ATTACHED FITTING
UNDER THE CURRENT AMBIENT CONDITIONS.
The processor will BEEP once per second and
the text “PRESS START” on the bottom line of the dis
play will
flash on and off.
Once you have verified that all measurements and parameters are correct, press the
START button
to begin
the fusion.
FAILURE TO VERIFY THAT THE FUSION INFORMATION IS CORRECT BEFORE STARTING A FUSION COULD
RESULT IN SIGNIFICANT DAMAGE TO PROPERTY, PERSONAL INJURY, AND/OR DEATH.