Kerotest Manufacturing
–
SHANNON & PAF III OPERATORS MANUAL - REV 3
Page 43 of 60
IT IS THE RESPONSIBILITY OF THE OPERATOR TO VERIFY THAT ALL THE INFORMATION DISPLAYED IS
CORRECT PER THE FITTING
MANUFACTURER’S RECOMMENDATIONS FOR FUSIN
G THE ATTACHED FITTING
UNDER THE CURRENT AMBIENT CONDITIONS.
If you press the
START button
to begin a fusion and receive Warning Code 55 (see page 53 for Error & Warning
Code Definitions), the processor will display a screen similar to the following:
WARNING 55 RECEIVED
Resistance 16.578
Min:1.21 Max:1.78
Hold START to clear
Press the
START button
to clear the warning code. The processor will display a screen similar to the following:
4 wire res. is out
of range. Ignore and
do secondary check?
START=Yes STOP=No
At this time, the operator has two options:
1.
Cancel the fusion.
2.
Perform the secondary check and attempt to continue fusing the fitting.
To CANCEL THE FUSION:
1.
Press the
STOP button
to cancel the fusion now. The processor will display a screen similar to the
following:
ERROR 102 RECEIVED
Resistance 16.578
Min:1.21 Max:1.78
Hold START to clear
2.
Press and hold the
START button
to clear the error code. Follow the prompts on the processor
display. See page 54 for information how to troubleshoot an Error Code 102.